Literature DB >> 21256045

Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: comparison of transfemoral and trans-apical approaches using Edwards Sapiens valve.

Parla Astarci1, David Glineur, Joelle Kefer, William D'Hoore, Jean Renkin, Jean-Louis Vanoverschelde, Gébrine El Khoury, Cécile Grandin.   

Abstract

OBJECTIVE: Cerebral embolization during trans-catheter aortic valve implantation (TAVI) has not been assessed clearly in the literature. Therefore, we compared the rate of cerebral embolisms with diffusion-weighted magnetic resonance imaging (DWI) in transfemoral (TF) and trans-apical (TA) approaches.
METHOD: Eighty patients benefited from TAVI between January 2008 and June 2010. Out of these, 35 were included in the study. Twenty-one were TF (group 1) and 14 TA (group 2). During the same period, 285 patients benefited from a conventional aortic valve surgery (aortic valve replacement (AVR)). Thirteen of these were also analyzed and considered as the control group (group 3). We systematically performed a DWI the day before the procedure and 48 h after. DWI studies were blindly analyzed by a neuroradiologist, and all patients had a clinical neurological assessment before and after the procedure, according the National Institutes of Health Stroke Scale (NIHSS).
RESULTS: Thirty-two patients in the TAVI group had new cerebral lesions: 19 in the TF group and 13 in the trans-apical group (p=NS). Mean number of embolic lesions per patient was 6.6 in group I and 6.0 in group II (p=NS). Mean volume of embolic lesions was 475.0 mm³ in group I and 2170.5 mm³ in group II (p=NS). In group III, one patient had one new cerebral lesion (p<0.05 vs TAVI) of 36.5 mm³ (p=NS vs TAVI). All patients were neurologically asymptomatic.
CONCLUSIONS: The incidence of silent cerebral embolic lesions after TAVI is significantly higher compared with the standard surgical AVR. The number of emboli is similar in the TF and TA groups but the volume tended to be higher in the TA group. However, there is no clinical impact of those lesions.
Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21256045     DOI: 10.1016/j.ejcts.2010.11.070

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  28 in total

1.  A novel device for endovascular native aortic valve resection for transapical transcatheter aortic valve implantation.

Authors:  Parla Astarci; David Glineur; Gébrine Elkhoury; Benoit Raucent
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-01-09

Review 2.  Almanac 2013: novel non-coronary cardiac interventions.

Authors:  Pascal Meier; Olaf Franzen; Alexandra J Lansky
Journal:  Wien Klin Wochenschr       Date:  2013-12       Impact factor: 1.704

3.  Transcatheter resection of the native aortic valve prior to endovalve implantation - A rational approach to reduce TAVI-induced complications.

Authors:  Parla Astarci; Pierre-Yves Etienne; Benoit Raucent; Xavier Bollen; Kahn Tranduy; David Glineur; Laurent Dekerchove; Philippe Noirhomme; Gébrine Elkhoury
Journal:  Ann Cardiothorac Surg       Date:  2012-07

4.  Transcatheter aortic valve implantation: Current status and future perspectives.

Authors:  Pablo Salinas; Raul Moreno; Jose L Lopez-Sendon
Journal:  World J Cardiol       Date:  2011-06-26

5.  Early cerebrovascular events after transcatheter aortic valve replacement: patient- and procedure-specific predictors.

Authors:  Dale Murdoch; Jonathon P Fanning
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

Review 6.  Incidence, predictors, origin and prevention of early and late neurological events after transcatheter aortic valve implantation (TAVI): a comprehensive review of current data.

Authors:  Philipp Kahlert; Fadi Al-Rashid; Björn Plicht; Heike Hildebrandt; Polykarpos Patsalis; Karim El Chilali; Daniel Wendt; Matthias Thielmann; Lars Bergmann; Eva Kottenberg; Marc Schlamann; Holger Eggebrecht; Heinz Jakob; Gerd Heusch; Thomas Konorza; Raimund Erbel
Journal:  J Thromb Thrombolysis       Date:  2013-05       Impact factor: 2.300

7.  Cognitive function after transapical aortic valve implantation: a single-centre study with 3-month follow-up.

Authors:  Stephan C Knipp; Philipp Kahlert; Daniel Jokisch; Marc Schlamann; Daniel Wendt; Christian Weimar; Heinz Jakob; Matthias Thielmann
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-11-11

Review 8.  The dementia of cardiac disease.

Authors:  Hurmina Muqtadar; Fernando D Testai; Philip B Gorelick
Journal:  Curr Cardiol Rep       Date:  2012-12       Impact factor: 2.931

Review 9.  Steps to translate preconditioning from basic research to the clinic.

Authors:  Frances R Bahjat; Raffaella Gesuete; Mary P Stenzel-Poore
Journal:  Transl Stroke Res       Date:  2012-11-02       Impact factor: 6.829

10.  Transcatheter Aortic Valve Replacement and Left Atrial Appendage Occlusion - A Stitch in Time?

Authors:  Sameer Gafoor; Luisa Heuer; Jennifer Franke; Stefan Bertog; Laura Vaskelyte; Ilona Hofmann; Horst Sievert
Journal:  Interv Cardiol       Date:  2014-04