Literature DB >> 21256036

Atomic Force Microscopy of bulk tendon samples: affect of location and fixation on tissue ultrastructure.

J M R Tilley1, A J Carr, J T Czernuszka.   

Abstract

Atomic Force Microscopy (AFM) is a surface characterisation technique which analyses topology. To date, AFM studies of tissue ultrastructure have focussed on single collagen fibrils extracted from different tissues prior to analysis. Using sample preparation techniques used in electron microscopy studies, this work uses AFM to analyse the collagen ultrastructure of bulk samples from bovine deep digital flexor tendons (DDFTs). DDFT ultrastructure in regions of the tendon which experience different loading conditions are compared. Samples are analysed post-freezing and post-aldehyde fixation with either 10% formalin or 4% glutaraldehyde in order to investigate the affect of tissue preservation on tissue ultrastructure. The results demonstrate that both fibril diameter and repeat unit of the tendon vary between different regions in the dorsoventral plane, with regions subjected to both tensile and compressive forces exhibiting smaller fibril diameter and repeat unit compared to regions subjected to tensile forces alone. These differences are detectable regardless of the tissue preservation technique used. However these measured differences do vary with preservation techniques with aldehyde-fixed samples exhibiting smaller fibril diameters and larger repeat units compared to frozen samples. These results demonstrate that AFM is a highly suitable technique for the characterisation of different ultrastructures in bulk samples but that it is important to be consistent in the choice of preservation technique.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21256036     DOI: 10.1016/j.micron.2011.01.001

Source DB:  PubMed          Journal:  Micron        ISSN: 0968-4328            Impact factor:   2.251


  6 in total

1.  Observation of collagen fibrils produced by osteosarcoma cells using atomic force microscopy.

Authors:  Osamu Hoshi
Journal:  Med Mol Morphol       Date:  2013-11-07       Impact factor: 2.309

2.  Morphological Characterisation of Unstained and Intact Tissue Micro-architecture by X-ray Computed Micro- and Nano-Tomography.

Authors:  Lucy A Walton; Robert S Bradley; Philip J Withers; Victoria L Newton; Rachel E B Watson; Clare Austin; Michael J Sherratt
Journal:  Sci Rep       Date:  2015-05-15       Impact factor: 4.379

3.  Visualising the 3D microstructure of stained and native intervertebral discs using X-ray microtomography.

Authors:  C M Disney; K Madi; A J Bodey; P D Lee; J A Hoyland; M J Sherratt
Journal:  Sci Rep       Date:  2017-11-24       Impact factor: 4.379

4.  Water-content related alterations in macro and micro scale tendon biomechanics.

Authors:  Pamela F Lozano; Mario Scholze; Carsten Babian; Holger Scheidt; Franziska Vielmuth; Jens Waschke; Benjamin Ondruschka; Niels Hammer
Journal:  Sci Rep       Date:  2019-05-27       Impact factor: 4.379

5.  Effect of tear size, corticosteroids and subacromial decompression surgery on the hierarchical structural properties of torn supraspinatus tendons.

Authors:  J M R Tilley; R J Murphy; S Chaudhury; J T Czernuszka; A J Carr
Journal:  Bone Joint Res       Date:  2014-08       Impact factor: 5.853

6.  Full-Field Strain Uncertainties and Residuals at the Cartilage-Bone Interface in Unstained Tissues Using Propagation-Based Phase-Contrast XCT and Digital Volume Correlation.

Authors:  Gianluca Tozzi; Marta Peña Fernández; Sarah Davis; Aikaterina Karali; Alexander Peter Kao; Gordon Blunn
Journal:  Materials (Basel)       Date:  2020-06-05       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.