Literature DB >> 2125428

End-tidal carbon dioxide monitoring during awake blind nasotracheal intubation.

S Dohi1, S Inomata, M Tanaka, Y Ishizawa, N Matsumiya.   

Abstract

STUDY
OBJECTIVE: To test the usefulness of the end-tidal carbon dioxide monitor in facilitating awake blind nasotracheal intubation in patients with potentially difficult airways.
DESIGN: Randomized, controlled comparison of regimen.
SETTING: Inpatient surgery clinic at a university hospital. PATIENTS: Sixty-one consecutive patients with potentially difficult airways.
INTERVENTIONS: After airway anesthesia with 4% lidocaine was administered to all patients, either fentanyl and diazepam (n = 30) or fentanyl alone (n = 31) was given intravenously before the awake blind nasotracheal intubation procedure.
MEASUREMENTS AND MAIN RESULTS: End-tidal carbon dioxide concentration, arterial blood pressure, heart rate, and arterial oxygen saturation (by pulse oximeter) were measured in each patient during the awake blind nasotracheal intubation procedure. The day after anesthesia and surgery, each patient was asked to assess the degree of discomfort experienced during the procedure. In 54 of 61 patients, the end-tidal carbon dioxide monitor facilitated awake blind nasotracheal intubation. End-tidal carbon dioxide was significantly higher in patients given both fentanyl and diazepam than in those given fentanyl alone (7.4% +/- 1.4% vs 5.9% +/- 0.9%, respectively; p less than 0.05), but no patient in either group recalled the awake intubation as extremely uncomfortable.
CONCLUSIONS: Monitoring of end-tidal carbon dioxide is useful and valuable in both facilitating blind nasotracheal intubation and avoiding profound hypoventilation.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2125428     DOI: 10.1016/0952-8180(90)90028-2

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  3 in total

1.  Esophageal tracheal combitube overcomes difficult intubation: flexion deformity of the cervical spine due to rheumatoid arthritis.

Authors:  Masaki Yurino
Journal:  J Anesth       Date:  1994-06       Impact factor: 2.078

2.  A learning curve of a novel multimodal endotracheal intubation assistant device for novices in a simulated airway: a prospective manikin trial with cumulative sum method.

Authors:  Ming Xia; Tianyi Xu; Shuang Cao; Chenyu Jin; Bei Pei; Hong Jiang
Journal:  Transl Pediatr       Date:  2022-08

3.  ETCO2 waveforms-assisted awake nasal fibreoptic intubation.

Authors:  Ting Li; Tongtong Liu; Meihong Li; Chuanhan Zhang; Wenlong Yao
Journal:  J Clin Monit Comput       Date:  2021-03-10       Impact factor: 1.977

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.