Literature DB >> 21254205

Magnetic resonance microimaging of human skin vasculature in vivo at 3 Tesla.

Elmar Laistler1, Robert Loewe, Ewald Moser.   

Abstract

MRI can be used to investigate human skin microvasculature in vivo, provided adequate spatial resolution. Therefore, the sensitivity of the experiment has to be optimized to achieve sufficient signal-to-noise ratio (SNR) within reasonable measurement time to minimize motion artifacts, improve patient comfort and save costs. In this work, the high sensitivity of a 15 mm surface coil and the signal strength of a 3 Tesla scanner, together with a three-dimensional gradient echo sequence and post-processing have been combined to obtain high SNR. Images of human skin with isotropic spatial resolution of 100 μm were acquired within 10 min and the cutaneous vasculature could be visualized in 3D [Correction made here after initial online publication.], based on three averaged scans. The presented method can be used for diagnosis and, due to its non-invasiveness, treatment monitoring of vascular pathologies in the skin, such as inflammation, vascular malformation, or neoangiogenesis in superficial tumors.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21254205     DOI: 10.1002/mrm.22743

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  A parallel imaging approach to wide-field MR microscopy.

Authors:  Mary Preston McDougall; Steven M Wright
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

2.  In vivo dual-modality photoacoustic and optical coherence tomography imaging of human dermatological pathologies.

Authors:  Behrooz Zabihian; Jessika Weingast; Mengyang Liu; Edward Zhang; Paul Beard; Hubert Pehamberger; Wolfgang Drexler; Boris Hermann
Journal:  Biomed Opt Express       Date:  2015-07-31       Impact factor: 3.732

3.  The physiological origin of task-evoked systemic artefacts in functional near infrared spectroscopy.

Authors:  Evgeniya Kirilina; Alexander Jelzow; Angela Heine; Michael Niessing; Heidrun Wabnitz; Rüdiger Brühl; Bernd Ittermann; Arthur M Jacobs; Ilias Tachtsidis
Journal:  Neuroimage       Date:  2012-03-09       Impact factor: 6.556

4.  In vivo MRI of the human finger at 7 T.

Authors:  Elmar Laistler; Barbara Dymerska; Jürgen Sieg; Sigrun Goluch; Roberta Frass-Kriegl; Andre Kuehne; Ewald Moser
Journal:  Magn Reson Med       Date:  2017-03-10       Impact factor: 4.668

5.  Non-invasive multimodal optical coherence and photoacoustic tomography for human skin imaging.

Authors:  Zhe Chen; Elisabet Rank; Kristen M Meiburger; Christoph Sinz; Andreas Hodul; Edward Zhang; Erich Hoover; Micheal Minneman; Jason Ensher; Paul C Beard; Harald Kittler; Rainer A Leitgeb; Wolfgang Drexler; Mengyang Liu
Journal:  Sci Rep       Date:  2017-12-21       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.