Literature DB >> 21254145

Placental volume and three-dimensional power Doppler analysis in prediction of pre-eclampsia and small for gestational age between Week 11 and 13 weeks and 6 days of gestation.

Marwan Odeh1, Ella Ophir, Olga Maximovsky, Vitali Grinin, Jacob Bornstein.   

Abstract

OBJECTIVE: To assess three-dimensional placental volume measurement and three-dimensional power Doppler (3D-PD) indices between 10 weeks and 6 days and 13 weeks and 6 days in predicting pregnancy-induced hypertension (PIH) and small for gestational age (SGA).
METHODS: Three hundred and eight women undergoing fetal nuchal translucency measurement were prospectively assessed using three-dimensional ultrasound in order to measure placental volume and 3D-PD indices: vascularization index (VI), flow index (FI) and vascularization flow index (VFI), using the VOCAL software. The outcome was scored as normal, PIH, SGA or both.
RESULTS: Eight women developed PIH and ten delivered SGA; and 17 developed PIH or SGA. The age, gestational age at the examination or delivery, number of the pregnancy and the nuchal translucency, were similar in all groups. The placental volume, FI and VFI were similar between the groups. The VI was significantly lower when PIH developed (7.86 ± 3.92 vs. 12.02 ± 7.09 in the normal group, P = 0.035). The crown-rump length (CRL) was significantly smaller in the group where either PIH or SGA developed compared to normal outcome (54.29 ± 6.50 and 59.04 ± 8.89, respectively, P = 0.02).
CONCLUSION: Placental volume is not appropriate for early prediction of PIH or SGA, whereas the VI may be of some potential in detection of PIH. The significance of small CRL in these patients should be further tested.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 21254145     DOI: 10.1002/pd.2697

Source DB:  PubMed          Journal:  Prenat Diagn        ISSN: 0197-3851            Impact factor:   3.050


  7 in total

1.  Combining early (<11 weeks' gestation) ultrasound features and maternal factors to predict small-for-gestational age neonates.

Authors:  Tracey J Hanchard; Bradley S de Vries; Ann E Quinton; Michael Sinosich; Jonathan A Hyett
Journal:  Australas J Ultrasound Med       Date:  2020-08-20

2.  Acute ambient air pollution exposure and placental Doppler results in the NICHD fetal growth studies - Singleton cohort.

Authors:  Marion Ouidir; Fasil Tekola-Ayele; Timothy Canty; Katherine L Grantz; Anthony Sciscione; Daniel Tong; Rena R Jones; Rajeshwari Sundaram; Andrew Williams; Danielle Stevens; Pauline Mendola
Journal:  Environ Res       Date:  2021-07-21       Impact factor: 6.498

3.  Placental vascularization alterations in hypertensive disorders complicating pregnancy (HDCP) and small for gestational age with HDCP using three-dimensional power doppler in a prospective case control study.

Authors:  Ting Yuan; Ting Zhang; Zhen Han
Journal:  BMC Pregnancy Childbirth       Date:  2015-10-05       Impact factor: 3.007

4.  Short-Term Exposure to Urban Air Pollution and Influences on Placental Vascularization Indexes.

Authors:  Karen Hettfleisch; Lisandra Stein Bernardes; Mariana Azevedo Carvalho; Luciana Duzolina Manfré Pastro; Sandra Elisabete Vieira; Silvia R D M Saldiva; Paulo Saldiva; Rossana Pulcineli Vieira Francisco
Journal:  Environ Health Perspect       Date:  2016-07-06       Impact factor: 9.031

Review 5.  Combined Screening for Early Detection of Pre-Eclampsia.

Authors:  Hee Jin Park; Sung Shin Shim; Dong Hyun Cha
Journal:  Int J Mol Sci       Date:  2015-08-04       Impact factor: 5.923

6.  Utero-placental vascularisation in normal and preeclamptic and intra-uterine growth restriction pregnancies: third trimester quantification using 3D power Doppler with comparison to placental vascular morphology (EVUPA): a prospective controlled study.

Authors:  Jie Duan; Anne-Claire Chabot-Lecoanet; Estelle Perdriolle-Galet; Christophe Christov; Gabriela Hossu; Aboubaker Cherifi; Olivier Morel
Journal:  BMJ Open       Date:  2016-03-31       Impact factor: 2.692

7.  Relationship between Plasma D-Dimer Concentration and Three-Dimensional Ultrasound Placental Volume in Women at Risk for Placental Vascular Diseases: A Monocentric Prospective Study.

Authors:  Cécile Fanget; Céline Chauleur; Amandine Stadler; Emilie Presles; Marie-Noëlle Varlet; Jean-Christophe Gris; Tiphaine Raia-Barjat
Journal:  PLoS One       Date:  2016-06-13       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.