Literature DB >> 21251845

Tricuspid valved stent implantation: novel stent with a self-expandable super-absorbent polymer.

Kenji Iino1, Lucian Lozonschi, Anja Metzner, Martin Marczynski-Bühlow, Jochen Renner, Jochen Cremer, Georg Lutter.   

Abstract

OBJECTIVE: Trans-catheter aortic and pulmonary valve replacement procedures can result in favorable outcomes in selected patients. The aim of this study was to investigate the functioning of a novel self-expanding valved stent with super-absorbent polymer (SAP) for minimally invasive replacement of the tricuspid valve.
METHODS: A newly designed nitinol stent with SAP was specially designed for the tricuspid annulus. This device was composed of right atrial anchoring elements, a left ventricular tubular stent, and a trileaflet bovine pericardial valve. The stent was coated with a waterproof material, and a pouch containing SAP for minimizing paravalvular leakage was placed beneath the atrial element. Seven pigs underwent minimally invasive off-pump tricuspid valved stent implantation. This was performed through a lower ministernotomy using a transventricular approach under transesophageal echocardiographic guidance. After 1 and 6h, a complete echocardiographic evaluation and hemodynamics (Swan-Ganz catheter) were performed.
RESULTS: Six of seven pigs exhibited normal hemodynamics immediately after tricuspid valved stent implantation and maintained stability for the entire period of monitoring. In one pig, a part of the atrial stent elements was deployed into the right ventricle, leading to significant paravalvular leakage, and died very soon. All subsequent animals survived with good results in the observation period. Accurate positioning of the valved stent was documented in six of seven pigs. SAP expanded and filled the gap between the stent and the native annulus in all animals. Mild paravalvular leakage was found in two of the six animals. Nevertheless, the observed leakage decreased to trace levels 6h after implantation. In the additional four pigs, only trace tricuspid regurgitation was revealed. No right ventricular outflow tract obstruction was detected.
CONCLUSIONS: Trans-apical off-pump tricuspid valved stent implantation is feasible in an acute experimental setting, and SAP may help to reduce paravalvular leakages.
Copyright © 2011. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21251845     DOI: 10.1016/j.ejcts.2010.11.051

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  2 in total

Review 1.  Management of tricuspid regurgitation.

Authors:  Michele De Bonis; Maurizio Taramasso; Elisabetta Lapenna; Ottavio Alfieri
Journal:  F1000Prime Rep       Date:  2014-07-08

2.  Transapical mitral valve implantation: the Lutter valve.

Authors:  G Lutter; S Pokorny; D Frank; J Cremer; L Lozonschi
Journal:  Heart Lung Vessel       Date:  2013
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.