Literature DB >> 21251637

Description and assessment of a common reference method for fluoroscopic and transesophageal echocardiographic localization and guidance of mitral periprosthetic transcatheter leak reduction.

Haïfa Mahjoub1, Stéphane Noble, Réda Ibrahim, Jeannot Potvin, Eileen O'Meara, Annie Dore, François Marcotte, Jacques Crépeau, Raoul Bonan, Asmaa Mansour, Denis Bouchard, Anique Ducharme, Arsène J Basmadjian.   

Abstract

OBJECTIVES: This study sought to describe and compare a novel fluoroscopic method and a 2-dimensional transesophageal echocardiographic (TEE) method to localize mitral periprosthetic leaks (PPLs) for transcatheter reduction.
BACKGROUND: Transcatheter reduction of significant regurgitation represents a modern and attractive alternative to surgery for the treatment of mitral PPL in high-risk patients. Accurate localization and precise communication between the echocardiographer and the interventional cardiologist are essential for procedural success.
METHODS: We analyzed TEE and fluoroscopic studies of patients with mitral PPL who underwent multiplane 2-dimensional TEE-guided transcatheter reduction in our institution. Periprosthetic leaks were routinely localized using the "surgeon's-view" time-clock method during periprocedural TEE assessments. The 2-dimensional TEE examinations were later retrospectively reviewed by an echocardiographer blinded to procedural TEE findings. A corresponding surgeon's-view time-clock method was plotted for fluoroscopic PPL localization. Using this fluoroscopic method, offline fluoroscopic images were reviewed by an independent interventional cardiologist blinded to TEE results. Agreement between methods was evaluated.
RESULTS: Complete imaging data were available for analysis in 20 patients who, between 2002 and 2009, underwent transcatheter reduction in which the defect was successfully crossed. There was excellent agreement between procedural TEE and retrospective TEE review for PPL localization (100%; p < 0.0001) and between fluoroscopic and procedural TEE localization (90%; 95% confidence interval [CI]: 77% to 100%; p = 0.0003). In the 2 cases where there was disagreement, fluoroscopic PPL localization was adjacent to TEE localization.
CONCLUSIONS: The surgeon's-view time-clock method of localizing PPL using 2-dimensional TEE is highly reproducible and allows fluoroscopic localization using the same reference system with very good agreement.
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21251637     DOI: 10.1016/j.jcin.2010.08.013

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  1 in total

1.  Transcatheter closure of paravalvular leaks: state of the art.

Authors:  I Cruz-Gonzalez; J C Rama-Merchan; J Rodríguez-Collado; J Martín-Moreiras; A Diego-Nieto; M Barreiro-Pérez; P L Sánchez
Journal:  Neth Heart J       Date:  2017-02       Impact factor: 2.380

  1 in total