The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissues.

Ralph van Brakel1, Herke Jan Noordmans1, Joost Frenken1, Rowland de Roode1, Gerard C de Wit1, Marco S Cune1.   

Abstract

OBJECTIVES: To determine the difference in light reflection of oral mucosa covering titanium (Ti) or zirconia (ZrO(2)) abutments as it relates to the thickness of the covering mucosa.
MATERIAL AND METHODS: Fifteen anterior implants (Astra Osseo speed(®)) in 11 patients were fitted with a Ti or a ZrO(2) abutment (cross-over, within-subject comparison). Hyper-spectral images were taken with a camera fitted on a surgical microscope. High-resolution images with 70 nm interval between 440 and 720 nm were obtained within 30 s (1392 × 1024 pixels). Black- and white-point reference was used for spatial and spectral normalization as well as correction for motion during exposure. Reflection spectra were extracted from the image on a line mid-buccal of the implant, starting 1 mm above the soft tissue continuing up to 3 mm apically.
RESULTS: Median soft tissue height is 2.3 mm (min: 1.2 mm and max: 3.1 mm). The buccal mucosa rapidly increases in the thickness, when moving apically. At 2.2 mm, thickness is 3 mm. No perceivable difference between the Ti and ZrO(2) abutment can be observed when the thickness of the mucosa is 2±0.1 mm (95% confidence interval) or more.
CONCLUSION: It is expected that the difference in light reflection of soft tissue covering Ti or ZrO(2) abutments is no longer noticeable for the human eye when the mucosa thickness exceeds 2 mm. Haemoglobin peaks in the reflection spectrum can be observed and make hyper-spectral imaging a practical and useful tool for measuring soft tissue health.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21251080     DOI: 10.1111/j.1600-0501.2010.02082.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  17 in total

1.  Impact of abutment material on peri-implant soft tissue color. An in vitro study.

Authors:  Leticia Sala; Antonio Bascones-Martínez; Ana Carrillo-de-Albornoz
Journal:  Clin Oral Investig       Date:  2016-11-22       Impact factor: 3.573

2.  Comprehensive review of surgical microscopes: technology development and medical applications.

Authors:  Ling Ma; Baowei Fei
Journal:  J Biomed Opt       Date:  2021-01       Impact factor: 3.170

3.  Long term follow-up of a full- arch rehabilitation with an implant-supported overdenture on four zirconia implants and a zirconia bar. A case report.

Authors:  Jesús Peláez; Judith Gelfo-Flores; Maria-Isabel Albanchez-González; Santiago Bazal-Bonelli; Carlos López-Suárez; Rubén Comino-Garayoa; Ramiro Mallagray-Martínez; Jorge Cortes-Bretón Brinkmann
Journal:  J Clin Exp Dent       Date:  2022-04-01

4.  Color variation induced by abutments in the superior anterior maxilla: an in vitro study in the pig gingiva.

Authors:  Ramin Atash; Mohamed-Reda Boularbah; Cetik Sibel
Journal:  J Adv Prosthodont       Date:  2016-12-15       Impact factor: 1.904

5.  Stock Versus CAD/CAM Customized Zirconia Implant Abutments - Clinical and Patient-Based Outcomes in a Randomized Controlled Clinical Trial.

Authors:  Ulf Schepke; Henny J A Meijer; Wouter Kerdijk; Gerry M Raghoebar; Marco Cune
Journal:  Clin Implant Dent Relat Res       Date:  2016-07-31       Impact factor: 3.932

Review 6.  Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis.

Authors:  Amr G ElHoussiney; He Zhang; Jinlin Song; Ping Ji; Lu Wang; Sheng Yang
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-26

7.  On the bulk degradation of yttria-stabilized nanocrystalline zirconia dental implant abutments: an electron backscatter diffraction study.

Authors:  V Ocelík; U Schepke; H Haji Rasoul; M S Cune; J Th M De Hosson
Journal:  J Mater Sci Mater Med       Date:  2017-07-06       Impact factor: 3.896

8.  A 3-Year Prospective Study on a Porcine-Derived Acellular Collagen Matrix to Re-Establish Convexity at the Buccal Aspect of Single Implants in the Molar Area: A Volumetric Analysis.

Authors:  Célien Eeckhout; Eline Bouckaert; Dagmar Verleyen; Thomas De Bruyckere; Jan Cosyn
Journal:  J Clin Med       Date:  2020-05-22       Impact factor: 4.241

9.  Tissue integration of zirconia and titanium implants with and without buccal dehiscence defects.

Authors:  Hyun-Chang Lim; Ronald Ernst Jung; Christoph Hans Franz Hämmerle; Myong Ji Kim; Kyeong-Won Paeng; Ui-Won Jung; Daniel Stefan Thoma
Journal:  J Periodontal Implant Sci       Date:  2018-06-30       Impact factor: 2.614

10.  Comparative in vitro study of two methods for gingival biotype assessment.

Authors:  Leticia Sala; Raquel Alonso-Pérez; Ruben Agustin-Panadero; Alberto Ferreiroa; Ana Carrillo-de-Albornoz
Journal:  J Clin Exp Dent       Date:  2018-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.