Comparison of noninvasive techniques to measure blood pressure in newborns.

Manoel A S Ribeiro1, Humberto H Fiori, Jorge H Luz, Jefferson P Piva, Nilza M E Ribeiro, Renato M Fiori.   

Abstract

OBJECTIVE: To compare blood pressure measurements in newborn infants using the flush method, pulse oximetry and oscillometry according to Doppler findings.
METHODS: Noninvasive blood pressure measurements were made using three techniques (flush method, pulse oximetry and oscillometry) in three groups of newborns: 15 normal term infants, 16 stable preterm infants, and 14 critically ill infants. All measurements were video recorded, edited separately, coded and analyzed independently by three neonatologists.
RESULTS: Fifty-seven measurements were made using each method. The flush method and pulse oximetry had a better correlation with Doppler findings than oscillometry (correlation coefficients: 0.89, 0.85, 0.71; p < 0.01). The difference between measurement means, their standard deviations and the 95% confidence intervals when compared with Doppler findings were: -5.2 ± 7.9 (-21.1:10.7) mmHg for the flush method; 0.4 ± 8.9 (-17.5:18.2) mmHg for pulse oximetry; and 6.4 ± 16.1 (-25.8:8.6) mmHg for oscillometry. The flush method had a better agreement with Doppler findings for the diagnosis of hypotension than oximetry and oscillometry.
CONCLUSIONS: The flush method and pulse oximetry seem to be useful techniques to measure systolic blood pressure in newborn infants; oscillometry had the poorest agreement with Doppler findings to detect hypotension.

Entities:  

Mesh:

Year:  2011        PMID: 21249265     DOI: 10.2223/JPED.2059

Source DB:  PubMed          Journal:  J Pediatr (Rio J)        ISSN: 0021-7557            Impact factor:   2.197


  1 in total

1.  Pulse oximetry vs non-invasive blood pressure/oscillometry to record blood pressure in neonates: A prospective observational study.

Authors:  Reenu Raju; Mathai Isac
Journal:  J Family Med Prim Care       Date:  2022-06-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.