Literature DB >> 21248245

The incidence and long-term clinical outcome of iatrogenic atrial septal defects secondary to transseptal catheterization with a 12F transseptal sheath.

Sheldon M Singh1, Pamela S Douglas, Vivek Y Reddy.   

Abstract

BACKGROUND: Studies assessing the presence of a residual iatrogenic atrial septal defect (iASD) after transseptal catheterization with 8F transseptal sheaths have suggested that the majority of these iASDs close within 6 months. However, these studies have been limited by small patient numbers and short follow-up. Additionally, there are a number of novel catheter procedures in interventional cardiology and electrophysiology that use larger transseptal sheaths. The objective of this study was to assess the incidence of and complications associated with iASDs in a large cohort of patients undergoing transseptal catheterization with a 12F transseptal sheath. METHODS AND
RESULTS: Patients (n=253) without a preexisting interatrial shunt undergoing WATCHMAN implantation as part of the PROTECT AF study were included in this current study. Patients underwent transesophageal echocardiography with echo-contrast immediately after the procedure and at 45 days and 6 months and 12 months. Eighty-seven percent of patients had an iASD immediately after the procedure, the majority of which sealed by 6 months (incidence of iASD, 34% at 45 days, 11% at 6 months, 7% at 12 months). Whereas the majority of iASDs were >3 mm in diameter immediately after the procedure, the minority of iASD were >3 mm during the follow-up period. Additionally, interatrial shunting was predominantly left-to-right when an iASD was present. There was no significant difference in the rate of stroke and/or systemic embolism during the follow-up period in patients with or without iASD.
CONCLUSIONS: Transseptal catheterization procedures with a large-diameter transseptal sheath have a high spontaneous closure rate of iASDs that is not associated with an increased rate of stroke/systemic embolization during long-term follow-up.

Entities:  

Mesh:

Year:  2011        PMID: 21248245     DOI: 10.1161/CIRCEP.110.959015

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  16 in total

Review 1.  Iatrogenic atrial septal defect: reassurance or inquisitiveness.

Authors:  Niyada Naksuk; Samuel J Asirvatham
Journal:  J Interv Card Electrophysiol       Date:  2018-04-22       Impact factor: 1.900

Review 2.  Catheter Ablation of Atrial Fibrillation in Patients with Hardware in the Heart - Septal Closure Devices, Mechanical Valves and More.

Authors:  Stefano Bartoletti; Pasquale Santangeli; Luigi DI Biase; Andrea Natale
Journal:  J Atr Fibrillation       Date:  2013-06-30

Review 3.  A Patient With Asymptomatic Cerebral Lesions During AF Ablation: How Much Should We Worry?

Authors:  Giovanni B Forleo; Domenico G Della Rocca; Carlo Lavalle; Massimo Mantica; Lida P Papavasileiou; Valentina Ribatti; Germana Panattoni; Luca Santini; Andrea Natale; Luigi Di Biase
Journal:  J Atr Fibrillation       Date:  2016-02-29

4.  Transcatheter balloon dilatation of cor triatriatum dexter with percutaneous atrial septal defect closure.

Authors:  Usman A Hasnie; Shane P Prejean; Asmaa N Ahmed; Mustafa I Ahmed; Mark A Law
Journal:  J Cardiol Cases       Date:  2021-07-23

5.  Persistence of an iatrogenic atrial septal defect after a second-generation cryoballoon ablation of atrial fibrillation.

Authors:  Tomonori Watanabe; Shinsuke Miyazaki; Takatsugu Kajiyama; Sadamitsu Ichijo; Takamitsu Takagi; Miyako Igarashi; Hiroaki Nakamura; Hiroshi Taniguchi; Hitoshi Hachiya; Yoshito Iesaka
Journal:  Heart Vessels       Date:  2018-03-17       Impact factor: 2.037

6.  Persistent iatrogenic atrial septal defects after pulmonary vein isolation: long-term follow-up with contrast transesophageal echocardiography.

Authors:  Allan Davies; Prasad Gunaruwan; Nicholas Collins; Malcolm Barlow; Nick Jackson; James Leitch
Journal:  J Interv Card Electrophysiol       Date:  2016-09-28       Impact factor: 1.900

Review 7.  Mechanical antithrombotic intervention by LAA occlusion in atrial fibrillation.

Authors:  Cheuk-Man Yu; Ahmed A Khattab; Stefan C Bertog; Alex P W Lee; Joey S W Kwong; Horst Sievert; Bernhard Meier
Journal:  Nat Rev Cardiol       Date:  2013-10-22       Impact factor: 32.419

8.  A modified percutaneous atrial balloon septoplasty for difficult transseptal puncture.

Authors:  Siyu Wang; Lei Zhao; Yuxing Wang; Xiandong Yin; Xinchun Yang; Ye Liu
Journal:  Medicine (Baltimore)       Date:  2021-07-16       Impact factor: 1.817

Review 9.  Current Devices and Complications Related to Transcatheter Mitral Valve Replacement: The Bumpy Road to the Top.

Authors:  Faraj Kargoli; Matteo Pagnesi; Kusha Rahgozar; Ythan Goldberg; Edwin Ho; Mei Chau; Antonio Colombo; Azeem Latib
Journal:  Front Cardiovasc Med       Date:  2021-06-11

10.  An implantable left atrial pressure sensor lead designed for percutaneous extraction using standard techniques.

Authors:  Victor Pretorius; Ulrika Birgersdotter-Green; J Thomas Heywood; Werner Hafelfinger; Dan E Gutfinger; Neal L Eigler; Charles J Love; William T Abraham
Journal:  Pacing Clin Electrophysiol       Date:  2013-02-28       Impact factor: 1.976

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.