Management of endothelial decompensation because of glaucoma shunt tube touch by Descemet membrane endothelial keratoplasty and tube revision.

Valery Bersudsky1, Aaron Treviño, Shimon Rumelt.   

Abstract

PURPOSE: To describe the trimming of a glaucoma shunt tube with Descemet membrane endothelial keratoplasty (DMEK) for the treatment of endothelial decompensation caused by tube-endothelium touch.
METHODS: An 84-year-old man with pseudoexfoliative glaucoma OU had endothelial decompensation because of the touch of the tube of an Ahmed glaucoma valve at the corneal endothelium OS. The best-corrected visual acuity decreased from 20/60 to counting fingers at 3 feet. The patient underwent uncomplicated trimming of the shunt tube and DMEK.
RESULTS: After surgery, the cornea became clear, and the best-corrected visual acuity improved to 20/60. The intraocular pressure remained normal (8-12 mm Hg) without antiglaucoma medications, and endothelial cell count remained stable in a follow-up of 12 months. No complications were encountered.
CONCLUSIONS: Glaucoma shunt tube trimming with DMEK may be considered in cases of endothelial decompensation because of tube-endothelium touch and may replace penetrating keratoplasty and other posterior lamellar procedures for such cases.

Entities:  

Mesh:

Year:  2011        PMID: 21242787     DOI: 10.1097/ICO.0b013e3181fb8378

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  6 in total

1.  Outcomes of Descemet Membrane Endothelial Keratoplasty in Patients With Previous Glaucoma Surgery.

Authors:  Carolina Aravena; Fei Yu; Sophie X Deng
Journal:  Cornea       Date:  2017-03       Impact factor: 2.651

2.  Scleral fixation of Ahmed glaucoma valve tube tip for adjustment of cornea-touching malposition.

Authors:  K T Ma; J H Kim; G J Seong; D S Jang; C Y Kim
Journal:  Eye (Lond)       Date:  2013-10-04       Impact factor: 3.775

3.  [Management of corneal endothelial decompensation with Descemet's membrane endothelial keratoplasty in a patient with Ahmed glaucoma valve implant].

Authors:  T Röck; K-U Bartz-Schmidt; D Röck; E Yoeruek
Journal:  Ophthalmologe       Date:  2014-05       Impact factor: 1.059

4.  Analysis of Schwalbe's Line (Limbal Smooth Zone) by Scanning Electron Microscopy and Optical Coherence Tomography in Human Eye Bank Eyes.

Authors:  Mark P Breazzano; Michael Fikhman; Jerrold L Abraham; Ann E Barker-Griffith
Journal:  J Ophthalmic Vis Res       Date:  2013-01

5.  Corneal decompensation following filtering surgery with the Ex-PRESS(®) mini glaucoma shunt device.

Authors:  Naoki Tojo; Atsushi Hayashi; Akio Miyakoshi
Journal:  Clin Ophthalmol       Date:  2015-03-17

Review 6.  The Results of the Use of Ahmed Valve in Refractory Glaucoma Surgery.

Authors:  Mukharram Mukhtaramovich Bikbov; Ilnur Ildarovich Khusnitdinov
Journal:  J Curr Glaucoma Pract       Date:  2016-02-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.