Literature DB >> 21242342

Neurothrombectomy devices for the treatment of acute ischemic stroke: state of the evidence.

William L Baker1, Jennifer A Colby, Vanita Tongbram, Ripple Talati, Isaac E Silverman, C Michael White, Jeffrey Kluger, Craig I Coleman.   

Abstract

BACKGROUND: Acute ischemic strokes are associated with poor outcomes and high health care burden. Evidence exists evaluating the use of neurothrombectomy devices in patients receiving currently recommended treatments that may have limited efficacy.
PURPOSE: To describe the state of the evidence supporting use of neurothrombectomy devices in the treatment of acute ischemic stroke. DATA SOURCES: MEDLINE, SCOPUS, the Cochrane Central Register of Controlled Trials, the Cochrane Database of Systematic Reviews, and Web of Science were searched, without language restrictions, from their inception through May 2010. The MEDLINE and Cochrane Central Register of Controlled Trials searches were updated through November 2010. STUDY SELECTION: Two independent investigators screened citations for human studies of any design or case series or case reports of patients with an acute ischemic stroke that evaluated a neurothrombectomy device and reported at least 1 clinical effectiveness outcome or harm. DATA EXTRACTION: Using standardized protocols, 2 independent investigators extracted information about study characteristics and outcomes, and a third reviewer resolved disagreement. DATA SYNTHESIS: 87 articles met eligibility criteria, including 18 prospective single-group studies, 7 noncomparative retrospective studies, and 62 case series or case reports. Two U.S. Food and Drug Administration (FDA)-cleared devices, the MERCI Retriever (Concentric Medical, Mountain View, California) (40%) and the Penumbra System (Penumbra, Alameda, California) (9%), represented a large portion of the available data. All prospective and retrospective studies provided data on successful recanalization with widely varying rates (43% to 78% with the MERCI Retriever and 83% to 100% with the Penumbra System). Rates of harms, including symptomatic (16 studies; 0% to 10% with the MERCI Retriever and 0% to 11% with the Penumbra System) or asymptomatic (13 studies; 28% to 43% and 1% to 30%, respectively) intracranial hemorrhage and vessel perforation or dissection (11 studies; 0% to 7% and 0% to 5%, respectively), also varied by device. Predictors of harm included older age, history of stroke, and higher baseline stroke severity scores, whereas successful recanalization was the sole predictor of good outcomes. LIMITATIONS: Most available data are from single-group, noncomparative studies. In addition, the patient population most likely to benefit from these devices is undetermined.
CONCLUSION: Currently available neurothrombectomy devices offer intriguing treatment options in patients with acute ischemic stroke. Future trials should use a randomized design, with adequate power to show equivalency or noninferiority between competing strategies or devices, and strive to identify populations that are most likely to benefit from use of neurothrombectomy devices. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.

Entities:  

Mesh:

Year:  2011        PMID: 21242342     DOI: 10.7326/0003-4819-154-4-201102150-00306

Source DB:  PubMed          Journal:  Ann Intern Med        ISSN: 0003-4819            Impact factor:   25.391


  27 in total

1.  [Management of acute ischemic stroke].

Authors:  C H Nolte; M Endres
Journal:  Internist (Berl)       Date:  2012-05       Impact factor: 0.743

2.  Dramatically reducing imaging-to-recanalization time in acute ischemic stroke: making choices.

Authors:  M Goyal; M A Almekhlafi
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-21       Impact factor: 3.825

3.  Susceptibility Vessel Sign on MRI Predicts Favorable Clinical Outcome in Patients with Anterior Circulation Acute Stroke Treated with Mechanical Thrombectomy.

Authors:  R Bourcier; S Volpi; B Guyomarch; B Daumas-Duport; A Lintia-Gaultier; C Papagiannaki; J M Serfaty; H Desal
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-27       Impact factor: 3.825

4.  Perfusion/Diffusion mismatch is valid and should be used for selecting delayed interventions.

Authors:  Stephen Davis; Bruce Campbell; Soren Christensen; Henry Ma; Patricia Desmond; Mark Parsons; Christopher Levi; Christopher Bladin; P Alan Barber; Geoffrey Donnan
Journal:  Transl Stroke Res       Date:  2012-04-18       Impact factor: 6.829

5.  MRI profile and response to endovascular reperfusion after stroke (DEFUSE 2): a prospective cohort study.

Authors:  Maarten G Lansberg; Matus Straka; Stephanie Kemp; Michael Mlynash; Lawrence R Wechsler; Tudor G Jovin; Michael J Wilder; Helmi L Lutsep; Todd J Czartoski; Richard A Bernstein; Cherylee W J Chang; Steven Warach; Franz Fazekas; Manabu Inoue; Aaryani Tipirneni; Scott A Hamilton; Greg Zaharchuk; Michael P Marks; Roland Bammer; Gregory W Albers
Journal:  Lancet Neurol       Date:  2012-09-04       Impact factor: 44.182

Review 6.  Revascularization grading in endovascular acute ischemic stroke therapy.

Authors:  O O Zaidat; M A Lazzaro; D S Liebeskind; N Janjua; L Wechsler; R G Nogueira; R C Edgell; J S Kalia; A Badruddin; J English; D Yavagal; J F Kirmani; A V Alexandrov; P Khatri
Journal:  Neurology       Date:  2012-09-25       Impact factor: 9.910

7.  [Industry-funded therapy studies: what is in the pipeline?].

Authors:  P D Schellinger; M Köhrmann; J Röther
Journal:  Nervenarzt       Date:  2012-10       Impact factor: 1.214

8.  Improving acute stroke management with computed tomography perfusion: a review of imaging basics and applications.

Authors:  C D d'Esterre; Enrico Fainardi; R I Aviv; T Y Lee
Journal:  Transl Stroke Res       Date:  2012-05-24       Impact factor: 6.829

9.  Value of Other Endovascular Techniques Among Patients with MERCI Device Failure during the Treatment of Acute Ischemic Stroke: What to do when MERCI fails?

Authors:  Ameer E Hassan; Mansoor M Aman; Saqib A Chauhdry; Mikayel Grigoryan; Wondwossen G Tekle; Gutavo J Rodriguez; Adnan I Qureshi
Journal:  J Vasc Interv Neurol       Date:  2013-02

10.  Value of Other Endovascular Techniques Among Patients with MERCI Device Failure during the Treatment of Acute Ischemic Stroke: What to do when MERCI fails?

Authors:  Ameer E Hassan; Mansoor M Aman; Saqib A Chauhdry; Mikayel Grigoryan; Wondwossen G Tekle; Gutavo J Rodriguez; Adnan I Qureshi
Journal:  J Vasc Interv Neurol       Date:  2013-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.