Literature DB >> 21242165

Monte Carlo simulations of the electric field close to the body in realistic environments for application in personal radiofrequency dosimetry.

S Iskra1, R McKenzie, I Cosic.   

Abstract

Personal dosemeters can play an important role in epidemiological studies and in radiofrequency safety programmes. In this study, a Monte Carlo approach is used in conjunction with the finite difference time domain method to obtain distributions of the electric field strength close to a human body model in simulated realistic environments. The field is a proxy for the response of an ideal body-worn electric field dosemeter. A set of eight environments were modelled based on the statistics of Rayleigh, Rice and log-normal fading to simulate outdoor and indoor multipath exposures at 450, 900 and 2100 MHz. Results indicate that a dosemeter mounted randomly within 10-50 mm of the adult or child body model (torso region) will on average underestimate the spatially averaged value of the incident electric field strength by a factor of 0.52 to 0.74 over the frequencies of 450, 900 and 2100 MHz. The uncertainty in results, assessed at the 95 % confidence level (between the 2.5th and 97.5th percentiles) was largest at 2100 MHz and smallest at 450 MHz.

Entities:  

Mesh:

Year:  2011        PMID: 21242165     DOI: 10.1093/rpd/ncq580

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Radiofrequency Exposure Amongst Employees of Mobile Network Operators and Broadcasters.

Authors:  Ian Litchfield; Martie van Tongeren; Tom Sorahan
Journal:  Radiat Prot Dosimetry       Date:  2017-06-15       Impact factor: 0.972

2.  A Personal, Distributed Exposimeter: Procedure for Design, Calibration, Validation, and Application.

Authors:  Arno Thielens; Peter Vanveerdeghem; Patrick Van Torre; Stephanie Gängler; Martin Röösli; Hendrik Rogier; Luc Martens; Wout Joseph
Journal:  Sensors (Basel)       Date:  2016-02-01       Impact factor: 3.576

3.  A Multi-Band Body-Worn Distributed Radio-Frequency Exposure Meter: Design, On-Body Calibration and Study of Body Morphology.

Authors:  Reza Aminzadeh; Arno Thielens; Sam Agneessens; Patrick Van Torre; Matthias Van den Bossche; Stefan Dongus; Marloes Eeftens; Anke Huss; Roel Vermeulen; René de Seze; Paul Mazet; Elisabeth Cardis; Hendrik Rogier; Martin Röösli; Luc Martens; Wout Joseph
Journal:  Sensors (Basel)       Date:  2018-01-18       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.