Measurement of the force-displacement response of in vivo human skin under a rich set of deformations.

Cormac Flynn1, Andrew Taberner, Poul Nielsen.   

Abstract

The non-linear, anisotropic, and viscoelastic properties of human skin vary according to location on the body, age, and individual. The measurement of skin's mechanical properties is important in several fields including medicine, cosmetics, and forensics. In this study, a novel force-sensitive micro-robot applied a rich set of three-dimensional deformations to the skin surface of different areas of the arms of 20 volunteers. The force-displacement response of each area in different directions was measured. All tested areas exhibited a non-linear, viscoelastic, and anisotropic force-displacement response. There was a wide quantitative variation in the stiffness of the response. For the right anterior forearm, the ratio of the maximum probe reaction force to maximum probe displacement ranged from 0.44 N mm(-1) to 1.45 N mm(-1). All volunteers exhibited similar qualitative anisotropic characteristics. For the anterior right forearm, the stiffest force-displacement response was when the probe displaced along the longitudinal axis of the forearm. The response of the anterior left forearm was stiffest in a direction 20° to the longitudinal axis of the forearm. The posterior upper arm was stiffest in a direction 90° to the longitudinal axis of the arm. The averaged posterior upper arm response was less stiff than the averaged anterior forearm response. The maximum probe force at 1.3mm probe displacement was 0.69N for the posterior upper arm and 1.1N for the right anterior forearm. The average energy loss during the loading-unloading cycle ranged from 11.9% to 34.2%. This data will be very useful for studying the non-linear, anisotropic, and viscoelastic behaviour of skin and also for generating material parameters for appropriate constitutive models.
Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21242096     DOI: 10.1016/j.medengphy.2010.12.017

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  2 in total

1.  Skin stiffness determined from occlusion of a horizontally running microvessel in response to skin surface pressure: a finite element study of sacral pressure ulcers.

Authors:  Hiroshi Yamada; Yoshiaki Inoue; Yuki Shimokawa; Keisuke Sakata
Journal:  Med Biol Eng Comput       Date:  2016-04-22       Impact factor: 2.602

2.  The Compressiometer: Toward a New Skin Tensiometer for Research and Surgical Planning.

Authors:  Karlijn M J Scheepens; Nick Marsidi; Roel E Genders; Tim Horeman-Franse
Journal:  IEEE J Transl Eng Health Med       Date:  2021-12-06       Impact factor: 3.316

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.