Literature DB >> 21238752

Screening of non-polar heterocyclic amines in urine by microextraction in packed sorbent-fluorimetric detection and confirmation by capillary liquid chromatography.

Fernando De Andrés1, Mohammed Zougagh, Gregorio Castañeda, José Luis Sánchez-Rojas, Angel Ríos.   

Abstract

A rapid and simple procedure for the direct screening of urine samples is described. The method involves microextraction in a packed sorbent (MEPS) that is on-line coupled to a capillary liquid chromatograph with fluorimetric detection. The overall arrangement works as a screening/confirmatory system for monitoring non-polar heterocyclic aromatic amines (HAAs) in urine samples. This configuration allows the selective retention of HAAs from urine on a C(18) MEPS cartridge integrated in the needle of a micro-well plate autosampler. Retained HAAs were eluted with methanol/water (90:10, v/v) and directly injected into the fluorimetric detector. This screening method provides a yes/no binary response that may require confirmation. The samples for which the concentration of HAAs was close to or above the established threshold limit (30 ng mL(-1)) were subjected to capillary liquid chromatography (CLC) for confirmation purposes. A mobile phase of acetonitrile and triethylamine (25 mM) at pH 2.5, through a gradient of composition at a flow rate of 20 μL min(-1), resulted in good separations between the analytes in less than 11 min. This confirmation method allowed the determination of the analytes in the 10-100 ng mL(-1) range for harmane and norharmane and from 20 to 200 ng mL(-1) for 3-amino-1,4-dimethyl-5H-pyrido-[4,3-b] indole (Trp-P-1), 3-amino-1-methyl-5H-pyrido-[4,3-b] indole (Trp-P-2), 2-amino-9H-pyrido-[2,3-b] indole (AαC) and 2-amino-3-methyl-9H-pyrido-[2,3-b] indole (MeAαC), with relative standard deviation (RSD) values between 2.12% and 3.73%, and limits of detection between 1.6 and 5.6 ng mL(-1) for all the HAAs.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21238752     DOI: 10.1016/j.talanta.2010.11.060

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  High-throughput and sensitive analysis of urinary heterocyclic aromatic amines using isotope-dilution liquid chromatography-tandem mass spectrometry and robotic sample preparation system.

Authors:  Li Zhang; Yang Xia; Baoyun Xia; Keegan J Nicodemus; James McGuffey; Ernest McGahee; Benjamin Blount; Lanqing Wang
Journal:  Anal Bioanal Chem       Date:  2016-09-29       Impact factor: 4.142

2.  Microextraction by Packed Sorbent (MEPS) and Solid-Phase Microextraction (SPME) as Sample Preparation Procedures for the Metabolomic Profiling of Urine.

Authors:  Catarina Silva; Carina Cavaco; Rosa Perestrelo; Jorge Pereira; José S Câmara
Journal:  Metabolites       Date:  2014-01-27
  2 in total