Literature DB >> 21236627

Serum metal ion concentration: comparison between small and large head metal-on-metal total hip arthroplasty.

Rhett K Hallows1, Christopher E Pelt, Jill A Erickson, Christopher L Peters.   

Abstract

The purpose of this study was to compare serum metal ion concentrations (chromium and cobalt) in 3 groups, 2 with metal-on-metal articulations and a control metal-on-polyethylene group. Forty-six patients with good to well-functioning hips were recruited for the study. Serum ion levels of all patients were drawn, and Harris Hip Score, University of California, Los Angeles activity score, and radiographs were performed. Serum chromium concentrations were significantly lower in the large head group compared with the small head group (P = .013). There was no difference in the cobalt concentrations between the 2 groups (P = .087). There was a significant difference between both metal-on-metal groups when compared with controls for both chromium and cobalt levels (P = .0005 and P = .0004, control vs small; P = .001 and P = .0001, control vs large, respectively).
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21236627     DOI: 10.1016/j.arth.2010.11.004

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Comparison between component designs with different femoral head size in metal-on-metal total hip arthroplasty; multicenter randomized prospective study.

Authors:  Wataru Ando; Kengo Yamamoto; Takashi Atsumi; Satoshi Tamaoki; Kazuhiro Oinuma; Hideaki Shiratsuchi; Hirohiko Tokunaga; Yutaka Inaba; Naomi Kobayashi; Masaharu Aihara; Kenji Ohzono
Journal:  J Orthop       Date:  2015-06-10

2.  What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?

Authors:  Nick Bayley; Habeeb Khan; Paul Grosso; Thomas Hupel; David Stevens; Matthew Snider; Emil Schemitsch; Paul Kuzyk
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

Review 3.  Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies.

Authors:  Albrecht Hartmann; Franziska Hannemann; Jörg Lützner; Andreas Seidler; Hans Drexler; Klaus-Peter Günther; Jochen Schmitt
Journal:  PLoS One       Date:  2013-08-07       Impact factor: 3.240

4.  Pseudotumours, cobalt and clinical outcome in small head metal-on-metal versus conventional metal-on-polyethylene total hip arthroplasty.

Authors:  Hugo C van der Veen; Inge Hf Reininga; Wierd P Zijlstra; Martijn F Boomsma; Sjoerd K Bulstra; Jos Jam van Raay
Journal:  Hip Int       Date:  2019-03-06       Impact factor: 2.135

5.  Does bearing size influence metal ion levels in large-head metal-on-metal total hip arthroplasty? A comparison of three total hip systems.

Authors:  James Smith; David Lee; Kamal Bali; Pam Railton; David Kinniburgh; Peter Faris; Deborah Marshall; Brian Burkart; James Powell
Journal:  J Orthop Surg Res       Date:  2014-01-28       Impact factor: 2.359

  5 in total