Literature DB >> 21236610

Hearing loss after noise exposure.

Revadi Govindaraju1, Rahmat Omar, Raman Rajagopalan, Ramli Norlisah, Ng Kwan-Hoong.   

Abstract

The higher field strength magnetic resonance imaging (MRI) such as 3 Tesla (T) and above generates noise that has potential detrimental effects on the hearing. Temporary threshold shifts following MRI examination have been reported for MRI with lower field strength. Such effect, however, have not been reported so far for a 3T MRI. We report a case that exemplifies the possible detrimental effects of a 3 T MRI generated noise on the auditory system. Our patient underwent investigation of his chronic backache in a 3 T MRI unit and developed hearing loss and tinnitus post-MRI examination. Hearing assessment was done using pure tone audiogram, distortion product otoacoustic emission (DPOAE) and brainstem electrical response audiometry (BERA) which revealed a unilateral sensorineural hearing loss which recovered within 3 days. However the tinnitus persisted. This is possibly a case of temporary threshold shift following noise exposure. However a sudden sensorineural hearing loss remains the other possibility.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21236610     DOI: 10.1016/j.anl.2010.12.006

Source DB:  PubMed          Journal:  Auris Nasus Larynx        ISSN: 0385-8146            Impact factor:   1.863


  5 in total

Review 1.  3 Tesla magnetic resonance imaging noise in standard head and neck sequence does not cause temporary threshold shift in high frequency.

Authors:  Elizabeth Yenn Lynn Lim; Ing Ping Tang; Mohammadreza Peyman; Norlisah Ramli; Prepageran Narayanan; Raman Rajagopalan
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-09-10       Impact factor: 2.503

2.  A Structure Design Method for Reduction of MRI Acoustic Noise.

Authors:  Jiaofen Nan; Nannan Zong; Qiqiang Chen; Liangliang Zhang; Qian Zheng; Yongquan Xia
Journal:  Comput Math Methods Med       Date:  2017-11-06       Impact factor: 2.238

3.  Hearing Thresholds Changes after MRI 1.5T of Head and Neck.

Authors:  Maryam Bahaloo; Mohammad Hossein Davari; Mohammad Sobhan; Seyyed Jalil Mirmohammadi; Mohammad Taghi Jalalian; Mohammad Javad Zare Sakhvidi; Farimah Shamsi; Sam Mirfendereski; Abolfazl Mollasadeghi; Amir Houshang Mehrparvar
Journal:  Radiol Res Pract       Date:  2019-06-17

4.  Does 3 Tesla Magnetic Resonance Imaging Have Adverse Effect on Cochlear Functions?

Authors:  Ugur Yildirim; Ozgur Kemal; Muzaffer Elmali; Figen Basar
Journal:  J Int Adv Otol       Date:  2021-09       Impact factor: 1.017

5.  Sensorineural hearing loss after magnetic resonance imaging.

Authors:  Abolfazl Mollasadeghi; Amir Houshang Mehrparvar; Saeid Atighechi; Mohammad Hossein Davari; Pedram Shokouh; Mehrdad Mostaghaci; Maryam Bahaloo
Journal:  Case Rep Radiol       Date:  2013-06-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.