Influence of contouring and hardness of foot orthoses on ratings of perceived comfort.

Kathryn Mills1, Peter Blanch, Bill Vicenzino.   

Abstract

PURPOSE: Comfort is a vital component of orthosis therapy. The purpose of this study was to examine what features of orthoses (design or hardness) influence the perception of comfort by using previously established footwear comfort measures: 100-mm visual analog scale (VAS) and ranking scale.
METHODS: Twenty subjects were consecutively allocated to two experiments consisting of five sessions of repeated measures. Comfort measures were taken from four prefabricated orthosis in each session using the VAS (experiment 1) and ranking scale (experiment 2). Subjects in experiment 1 were also asked to rate each orthosis relative to their shoe using a criterion scale. Measures were taken in both walking and jogging.
RESULTS: A soft-flat orthosis was found to be significantly more comfortable than all contoured orthoses, including one of the same hardness using both the VAS and ranking scale. Using the VAS, differences between the soft-flat and contoured orthoses were also found to be clinically meaningful for dimensions of overall comfort and arch cushioning (>10.2 mm). Perceived comfort of orthoses significantly differed between walking and jogging on the VAS but was not clinically meaningful. Comparisons between the VAS and criterion scale detected a VAS difference of 11.34 mm between orthoses judged as comfortable as my shoe and slightly more comfortable than my shoe. There was a VAS difference of 17.49 mm between orthoses judged as comfortable as my shoe and slightly less comfortable than my shoe.
CONCLUSIONS: Healthy subjects prioritize contouring over hardness when judging the comfort of orthoses. Clinically meaningful changes were required to change or enhance the comfort of orthoses standardized in material type and fabrication.

Entities:  

Mesh:

Year:  2011        PMID: 21233775     DOI: 10.1249/MSS.0b013e31820e783f

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  7 in total

1.  Somatosensory Perception of Running Shoe Mass may be influenced by Extended Wearing Time or Inclusion of a Personal Reference Shoe, Depending on Testing Method.

Authors:  James G Saxton; Benjamin R Mardis; Christopher L Kliethermes; David S Senchina
Journal:  Int J Exerc Sci       Date:  2020-02-01

2.  Activation of Neck and Low-Back Muscles Is Reduced with the Use of a Neck Balance System Together with a Lumbar Support in Urban Drivers.

Authors:  Federica Menotti; Luciana Labanca; Luca Laudani; Arrigo Giombini; Fabio Pigozzi; Andrea Macaluso
Journal:  PLoS One       Date:  2015-10-16       Impact factor: 3.240

3.  The effect of foot orthoses with forefoot cushioning or metatarsal pad on forefoot peak plantar pressure in running.

Authors:  Michaela Hähni; Anja Hirschmüller; Heiner Baur
Journal:  J Foot Ankle Res       Date:  2016-11-16       Impact factor: 2.303

4.  Development and evaluation of a dual density insole for people standing for long periods of time at work.

Authors:  Jennifer Anderson; Anita E Williams; Chris Nester
Journal:  J Foot Ankle Res       Date:  2020-07-08       Impact factor: 2.303

5.  Comparative Study of the Effects of Customized 3D printed insole and Prefabricated Insole on Plantar Pressure and Comfort in Patients with Symptomatic Flatfoot.

Authors:  Rui Xu; Zhonghan Wang; Zhenxiao Ren; Tingjian Ma; Zhe Jia; Shuyan Fang; Hui Jin
Journal:  Med Sci Monit       Date:  2019-05-12

6.  A study of the immediate effects of glycerine-filled insoles, contoured prefabricated orthoses and flat insoles on single-leg balance, gait patterns and perceived comfort in healthy adults.

Authors:  Anna L Hatton; François Hug; Brooke C M Brown; Leon P Green; Jacob R Hughes; Jarrad King; Emma J Orgar; Kate Surman; Bill Vicenzino
Journal:  J Foot Ankle Res       Date:  2015-09-07       Impact factor: 2.303

7.  Effect of custom-made and prefabricated foot orthoses on kinematic parameters during an intense prolonged run.

Authors:  Marina Gil-Calvo; Irene Jimenez-Perez; Jose Ignacio Priego-Quesada; Ángel G Lucas-Cuevas; Pedro Pérez-Soriano
Journal:  PLoS One       Date:  2020-03-26       Impact factor: 3.240