Extremity exposure in nuclear medicine: preliminary results of a European study.

M Sans Merce1, N Ruiz, I Barth, A Carnicer, L Donadille, P Ferrari, M Fulop, M Ginjaume, G Gualdrini, S Krim, F Mariotti, X Ortega, A Rimpler, F Vanhavere, S Baechler.   

Abstract

The Work Package 4 of the ORAMED project, a collaborative project (2008-11) supported by the European Commission within its seventh Framework Programme, is concerned with the optimisation of the extremity dosimetry of medical staff in nuclear medicine. To evaluate the extremity doses and dose distributions across the hands of medical staff working in nuclear medicine departments, an extensive measurement programme has been started in 32 nuclear medicine departments in Europe. This was done using a standard protocol recording all relevant information for radiation exposure, i.e. radiation protection devices and tools. This study shows the preliminary results obtained for this measurement campaign. For diagnostic purposes, the two most-used radionuclides were considered: (99m)Tc and (18)F. For therapeutic treatments, Zevalin(®) and DOTATOC (both labelled with (90)Y) were chosen. Large variations of doses were observed across the hands depending on different parameters. Furthermore, this study highlights the importance of the positioning of the extremity dosemeter for a correct estimate of the maximum skin doses.

Mesh:

Substances:

Year:  2011        PMID: 21233097     DOI: 10.1093/rpd/ncq574

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Validation of a new protocol for ¹⁸F-FDG infusion using an automatic combined dispenser and injector system.

Authors:  Michela Lecchi; Giovanni Lucignani; Claudio Maioli; Giuseppe Ignelzi; Angelo Del Sole
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-06-28       Impact factor: 9.236

2.  Commentary on: "Occupational radiation exposure of medical staff performing ⁹⁰Y-loaded microsphere radioembolization".

Authors:  Vanessa L Gates; Ahmed Gabr; Joseph Kallini; Robert J Lewandowski; Riad Salem
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-05       Impact factor: 9.236

3.  Effect of dosimeter's position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT.

Authors:  Fabien Salesses; Paul Perez; Aline E Maillard; Julie Blanchard; Sabine Mallard; Laurence Bordenave
Journal:  EJNMMI Phys       Date:  2016-08-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.