Surgical punctal occlusion with a high heat-energy releasing cautery device for severe dry eye with recurrent punctal plug extrusion.

Emii Ohba1, Murat Dogru, Eri Hosaka, Asako Yamazaki, Rie Asaga, Yukako Tatematsu, Yoko Ogawa, Kazuo Tsubota, Eiki Goto.   

Abstract

PURPOSE: To report the rate of recanalization and the efficacy of punctal occlusion surgery with a high heat-energy-releasing cautery device in patients with severe dry eye disease and recurrent punctal plug extrusion.
DESIGN: Prospective, interventional case series.
METHODS: Seventy puncta from 44 eyes of 28 dry eye patients underwent punctal occlusion with thermal cautery. All patients had a history of recurrent punctal plug extrusion. A high heat-energy-releasing thermal cautery device (Optemp II V; Alcon Japan) was used for punctal occlusion surgery. Symptom scores, best-corrected visual acuity, fluorescein staining score, rose bengal staining score, tear film break-up time, and Schirmer test values were compared before and 3 months after the surgery. Rate of punctal recanalization also was examined.
RESULTS: Three months after surgical cauterization, symptom score decreased from 3.9 ± 0.23 to 0.56 ± 0.84 (P < .0001). Logarithm of the minimal angle of resolution best-corrected visual acuity improved from 0.11 ± 0.30 to 0.013 ± 0.22 (P = .003). Fluorescein staining score, rose bengal staining score, tear film break-up time, and the Schirmer test value also improved significantly after the surgery. Only 1 of 70 puncta recanalized after thermal cauterization (1.4%).
CONCLUSIONS: Punctal occlusion with the high heat-energy-releasing cautery device not only was associated with a low recanalization rate, but also with improvements in ocular surface wetness and better visual acuity.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21232733     DOI: 10.1016/j.ajo.2010.08.045

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  4 in total

1.  The Use of Electrotherapeutics in Ophthalmology.

Authors:  Kieu-Yen Luu; Min Zhao; Mark J Mannis
Journal:  Am J Ophthalmol       Date:  2019-11-15       Impact factor: 5.258

2.  Post-LASIK dry eye.

Authors:  Roni M Shtein
Journal:  Expert Rev Ophthalmol       Date:  2011-10

3.  Near-infrared laser thermal conjunctivoplasty.

Authors:  Jianlong Yang; Rahul Chandwani; Varun Gopinatth; Tim Boyce; Stephen C Pflugfelder; David Huang; Gangjun Liu
Journal:  Sci Rep       Date:  2018-03-01       Impact factor: 4.379

4.  Long-term Outcomes of Punctal Cauterization in the Management of Ocular Surface Diseases.

Authors:  Yvonne Wang; Jimena Tatiana Carreno-Galeano; Rohan Bir Singh; Reza Dana; Jia Yin
Journal:  Cornea       Date:  2021-02-01       Impact factor: 3.152

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.