Literature DB >> 21232641

Bone cell-materials interactions and Ni ion release of anodized equiatomic NiTi alloy.

Sheldon A Bernard1, Vamsi Krishna Balla, Neal M Davies, Susmita Bose, Amit Bandyopadhyay.   

Abstract

A laser processed NiTi alloy was anodized for different n class="Chemical">times in H(2)SO(4) electrolyte with varying pH to create biocompatible surfaces with low Ni ion release as well as bioactive surfaces to enhance biocompatibility and bone cell-material interactions. The anodized surfaces were assessed for their in vitro cell-material interactions using human fetal osteoblast (hFOB) cells for 3, 7 and 11 days, and Ni ion release up to 8 weeks in simulated body fluids. The results were correlated with the surface morphologies of anodized surfaces characterized using field-emission scanning electron microscopy (FESEM). The results show that anodization creates a surface with nano/micro-roughness depending on the anodization conditions. The hydrophilicity of the NiTi surface was found to improve after anodization, as shown by the lower contact angles in cell medium, which dropped from 32° to <5°. The improved wettability of anodized surfaces is further corroborated by their high surface energy, comparable with that of commercially pure Ti. Relatively high surface energies, especially the polar component, and nano/micro surface features of anodized surfaces significantly increased the number of living cells and their adherence and growth on these surfaces. Finally, a significant drop in Ni ion release from 268±11 to 136±15 ppb was observed for NiTi surfaces after anodization. This work indicates that anodization of a NiTi alloy has a positive influence on the surface energy and surface morphology, which in turn improves bone cell-material interactions and reduces Ni ion release in vitro.
Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21232641      PMCID: PMC3048762          DOI: 10.1016/j.actbio.2011.01.004

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  26 in total

1.  Qualitative and quantitative study of human osteoblast adhesion on materials with various surface roughnesses.

Authors:  K Anselme; M Bigerelle; B Noel; E Dufresne; D Judas; A Iost; P Hardouin
Journal:  J Biomed Mater Res       Date:  2000-02

2.  Behavior of human osteoblastic cells on stoichiometric hydroxyapatite and type A carbonate apatite: role of surface energy.

Authors:  S A Redey; M Nardin; D Bernache-Assolant; C Rey; P Delannoy; L Sedel; P J Marie
Journal:  J Biomed Mater Res       Date:  2000-06-05

3.  Surface oxidation of NiTi shape memory alloy.

Authors:  G S Firstov; R G Vitchev; H Kumar; B Blanpain; J Van Humbeeck
Journal:  Biomaterials       Date:  2002-12       Impact factor: 12.479

4.  Abnormal trace metals in man--nickel.

Authors:  H A SCHROEDER; J J BALASSA; I H TIPTON
Journal:  J Chronic Dis       Date:  1962-01

5.  The influence of surface energy on competitive protein adsorption on oxidized NiTi surfaces.

Authors:  Alexandra Michiardi; Conrado Aparicio; Buddy D Ratner; Josep A Planell; Javier Gil
Journal:  Biomaterials       Date:  2007-02       Impact factor: 12.479

6.  Fabrication of porous NiTi shape memory alloy structures using laser engineered net shaping.

Authors:  B Vamsi Krishna; Susmita Bose; Amit Bandyopadhyay
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-05       Impact factor: 3.368

7.  Relative importance of surface wettability and charged functional groups on NIH 3T3 fibroblast attachment, spreading, and cytoskeletal organization.

Authors:  K Webb; V Hlady; P A Tresco
Journal:  J Biomed Mater Res       Date:  1998-09-05

8.  Direct laser processing of a tantalum coating on titanium for bone replacement structures.

Authors:  Vamsi Krishna Balla; Shashwat Banerjee; Susmita Bose; Amit Bandyopadhyay
Journal:  Acta Biomater       Date:  2009-12-04       Impact factor: 8.947

9.  Establishment of nickel-specific T cell lines from patients with allergic contact dermatitis: comparison of different protocols.

Authors:  H Bour; J F Nicolas; J L Garrigue; A Demidem; D Schmitt
Journal:  Clin Immunol Immunopathol       Date:  1994-10

10.  Calcium phosphate coating of nickel-titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets.

Authors:  Jongsik Choi; Denise Bogdanski; Manfred Köller; Stefan A Esenwein; Dietmar Müller; Gert Muhr; Matthias Epple
Journal:  Biomaterials       Date:  2003-09       Impact factor: 12.479

View more
  5 in total

1.  Influence of sodium hypochlorite treatment of electropolished and magnetoelectropolished nitinol surfaces on adhesion and proliferation of MC3T3 pre-osteoblast cells.

Authors:  Ryszard Rokicki; Waseem Haider; Tadeusz Hryniewicz
Journal:  J Mater Sci Mater Med       Date:  2012-06-03       Impact factor: 3.896

2.  TiNi shape memory alloy coated with tungsten: a novel approach for biomedical applications.

Authors:  Huafang Li; Yufeng Zheng; Y T Pei; J Th M De Hosson
Journal:  J Mater Sci Mater Med       Date:  2014-01-31       Impact factor: 3.896

3.  Surface characterization and biocompatibility of titanium alloys implanted with nitrogen by Hardion+ technology.

Authors:  D M Gordin; T Gloriant; V Chane-Pane; D Busardo; V Mitran; D Höche; C Vasilescu; S I Drob; A Cimpean
Journal:  J Mater Sci Mater Med       Date:  2012-08-24       Impact factor: 3.896

4.  Biocompatibility and Inflammatory Potential of Titanium Alloys Cultivated with Human Osteoblasts, Fibroblasts and Macrophages.

Authors:  Jana Markhoff; Martin Krogull; Christian Schulze; Christian Rotsch; Sandra Hunger; Rainer Bader
Journal:  Materials (Basel)       Date:  2017-01-10       Impact factor: 3.623

5.  Structure and properties of composite surface layers produced on NiTi shape memory alloy by a hybrid method.

Authors:  Justyna Witkowska; Agnieszka Sowińska; Elżbieta Czarnowska; Tomasz Płociński; Bogusław Rajchel; Michał Tarnowski; Tadeusz Wierzchoń
Journal:  J Mater Sci Mater Med       Date:  2018-07-17       Impact factor: 3.896

  5 in total