Literature DB >> 21229236

Development of amperometric magnetogenosensors coupled to asymmetric PCR for the specific detection of Streptococcus pneumoniae.

Susana Campuzano1, María Pedrero, José L García, Ernesto García, Pedro García, José M Pingarrón.   

Abstract

A disposable magnetogenosensor for the rapid, specific and sensitive detection of Streptococcus pneumoniae is reported. The developed procedure involves the use of streptavidin-modified magnetic beads, a specific biotinylated capture probe that hybridizes with a specific region of lytA, the gene encoding the pneumococcal major autolysin, and appropriate primers for asymmetric polymerase chain reaction (PCR) amplification. Capture probes and amplicons specific for S. pneumoniae were selected by a careful analysis of all lytA alleles available. The selected primers amplify a 235-bp fragment of pneumococcal lytA. A detection limit (LOD) of 5.1 nM was obtained for a 20-mer synthetic target DNA without any amplification protocol, while the LOD for the asymmetric PCR amplicon was 1.1 nM. A RSD value of 6.9% was obtained for measurements carried out with seven different genosensors for 1.1-nM aPCR product. The strict specificity of the designed primers was demonstrated by aPCR amplification of genomic DNA prepared from different bacteria, including some closely related streptococci. Direct asymmetric PCR (daPCR), using cells directly from broth cultures of S. pneumoniae, showed that daPCR products could be prepared with as few as 2 colony-forming units (CFU). Furthermore, this methodology did not show any cross-reaction with closely related streptococci such as Streptococcus mitis (or Streptococcus pseudopneumoniae) even when present in the culture at concentrations up to 10(5) times higher than that of S. pneumoniae. Preliminary data for rapid detection of pneumococcus directly in clinical samples has shown that it is possible to discriminate between non-inoculated blood and urine samples and samples inoculated with only 10(3) CFU mL(-1)  S. pneumoniae.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21229236     DOI: 10.1007/s00216-010-4645-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

Review 1.  Molecular Biosensors for Electrochemical Detection of Infectious Pathogens in Liquid Biopsies: Current Trends and Challenges.

Authors:  Susana Campuzano; Paloma Yáñez-Sedeño; José Manuel Pingarrón
Journal:  Sensors (Basel)       Date:  2017-11-03       Impact factor: 3.576

Review 2.  Electrochemical Genosensing of Circulating Biomarkers.

Authors:  Susana Campuzano; Paloma Yáñez-Sedeño; José Manuel Pingarrón
Journal:  Sensors (Basel)       Date:  2017-04-14       Impact factor: 3.576

Review 3.  Detection of Salmonella in Food Matrices, from Conventional Methods to Recent Aptamer-Sensing Technologies.

Authors:  Nathalie Paniel; Thierry Noguer
Journal:  Foods       Date:  2019-09-01

4.  Poly-L-lysine Coated Surfaces for Ultrasensitive Nucleic Acid Detection.

Authors:  Filiz Kuralay; Nilgün Dükar; Yaşar Bayramlı
Journal:  Electroanalysis       Date:  2018-05-24       Impact factor: 3.223

Review 5.  Magnetic Beads-Based Electrochemical Sensors Applied to the Detection and Quantification of Bioterrorism/Biohazard Agents.

Authors:  María Pedrero; Susana Campuzano; José M Pingarrón
Journal:  Electroanalysis       Date:  2011-11-18       Impact factor: 3.223

Review 6.  Magnetic Particles Coupled to Disposable Screen Printed Transducers for Electrochemical Biosensing.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2016-09-25       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.