Literature DB >> 21228590

Why assistive technology is needed for probing of dry weight.

Arjun D Sinha1.   

Abstract

Despite advancements in dialysis therapy, the subjective clinical examination still remains the standard of care in managing volume removal in chronic dialysis. While there is no definitive trial establishing that dry weight management guided by an assistive technology is superior to the clinical method, there is ample evidence that there is a need for these technologies to be developed. Mortality, cardiovascular morbidity, and sequelae of volume overload remain far too common under the current paradigm. Recent studies indicate that the mortality associated with volume overload is independent of hypertension, suggesting that if mortality is to be improved, then a measure of volume independent of blood pressure must be developed. Even when considered as an integrated whole, the clinical method is inaccurate at setting dry weight when compared to the use of assistive technologies. A recent secondary analysis of a randomized trial showed that relative plasma volume (RPV) slope is responsive to change in volume status and may be useful in guiding therapy for hypertension. The only large randomized trial to investigate the ability of an assistive technology to manage volume removal in hemodialysis patients is the Crit-Line Intradialytic Monitoring Benefit Study, which found harm associated with RPV monitoring. However, the design of this trial did not require the RPV group to actually receive this intervention. Assistive technologies offer an opportunity to improve on the subjective clinical exam for the setting of dry weight, but well designed and adequately powered clinical trials are needed.
Copyright © 2011 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2011        PMID: 21228590     DOI: 10.1159/000321840

Source DB:  PubMed          Journal:  Blood Purif        ISSN: 0253-5068            Impact factor:   2.614


  8 in total

1.  Efficacy of different hemodialysis methods on dendritic cell marker CD40 and CD80 and platelet activation marker CD62P and P10 in patients with chronic renal failure.

Authors:  Xin-Fang Wang; Bei-Hao Zhang; Xiao-Qing Lu; Pei Wang
Journal:  J Clin Lab Anal       Date:  2018-11-29       Impact factor: 2.352

2.  Fluid assessment in dialysis patients by point-of-care magnetic relaxometry.

Authors:  Lina A Colucci; Kristin M Corapi; Matthew Li; Xavier Vela Parada; Andrew S Allegretti; Herbert Y Lin; Dennis A Ausiello; Matthew S Rosen; Michael J Cima
Journal:  Sci Transl Med       Date:  2019-07-24       Impact factor: 17.956

Review 3.  Epidemiology, diagnosis and management of hypertension among patients on chronic dialysis.

Authors:  Panagiotis I Georgianos; Rajiv Agarwal
Journal:  Nat Rev Nephrol       Date:  2016-08-30       Impact factor: 28.314

4.  B-type natriuretic peptide is not a volume marker among patients on hemodialysis.

Authors:  Rajiv Agarwal
Journal:  Nephrol Dial Transplant       Date:  2013-03-22       Impact factor: 5.992

5.  Hand-carried ultrasound use in clinical nephrology: Case report.

Authors:  Kathryn D Winters; Stephanie Toth-Manikowski; Carol Martire; Tariq Shafi
Journal:  Medicine (Baltimore)       Date:  2016-07       Impact factor: 1.889

6.  Blood pressure and volume management in dialysis: conclusions from a Kidney Disease: Improving Global Outcomes (KDIGO) Controversies Conference.

Authors:  Jennifer E Flythe; Tara I Chang; Martin P Gallagher; Elizabeth Lindley; Magdalena Madero; Pantelis A Sarafidis; Mark L Unruh; Angela Yee-Moon Wang; Daniel E Weiner; Michael Cheung; Michel Jadoul; Wolfgang C Winkelmayer; Kevan R Polkinghorne
Journal:  Kidney Int       Date:  2020-03-08       Impact factor: 10.612

7.  Blood volume analysis as a guide for dry weight determination in chronic hemodialysis patients: a crossover study.

Authors:  Line Malha; Hasan Fattah; Frank Modersitzki; David S Goldfarb
Journal:  BMC Nephrol       Date:  2019-02-11       Impact factor: 2.388

8.  Fluid volume expansion and depletion in hemodialysis patients lack association with clinical parameters.

Authors:  Sylvia Kalainy; Ryan Reid; Kailash Jindal; Neesh Pannu; Branko Braam
Journal:  Can J Kidney Health Dis       Date:  2015-12-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.