Literature DB >> 21227532

Metal artifact reduction in dental CT images using polar mathematical morphology.

Valery Naranjo1, Roberto Lloréns, Mariano Alcañiz, Fernando López-Mir.   

Abstract

Most dental implant planning systems use a 3D representation of the CT scan of the patient under study as it provides a more intuitive view of the human jaw. The presence of metallic objects in human jaws, such as amalgam or gold fillings, provokes several artifacts like streaking and beam hardening which makes the reconstruction process difficult. In order to reduce these artifacts, several methods have been proposed using the raw data, directly obtained from the tomographs, in different ways. However, in DICOM-based applications this information is not available, and thus the need of a new method that handles this task in the DICOM domain. The presented method performs a morphological filtering in the polar domain yielding output images less affected by artifacts (even in cases of multiple metallic objects) without causing significant smoothing of the anatomic structures, which allows a great improvement in the 3D reconstruction. The algorithm has been automated and compared to other image denoising methods with successful results.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21227532     DOI: 10.1016/j.cmpb.2010.11.009

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  8 in total

1.  Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.

Authors:  W Wuest; M S May; M Brand; N Bayerl; A Krauss; M Uder; M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

2.  Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs.

Authors:  R Patcas; G Markic; L Müller; O Ullrich; T Peltomäki; C J Kellenberger; C A Karlo
Journal:  Dentomaxillofac Radiol       Date:  2012-05-03       Impact factor: 2.419

3.  Inpainting-filtering for metal artifact reduction (IMIF-MAR) in computed tomography.

Authors:  Yakdiel Rodríguez-Gallo; Rubén Orozco-Morales; Marlen Pérez-Díaz
Journal:  Phys Eng Sci Med       Date:  2021-03-24

4.  Monoenergetic computed tomography reconstructions reduce beam hardening artifacts from dental restorations.

Authors:  Paul Stolzmann; Sebastian Winklhofer; Nicole Schwendener; Hatem Alkadhi; Michael J Thali; Thomas D Ruder
Journal:  Forensic Sci Med Pathol       Date:  2013-03-20       Impact factor: 2.007

5.  Frequency split metal artefact reduction in pelvic computed tomography.

Authors:  M M Lell; E Meyer; M Schmid; R Raupach; M S May; M Uder; M Kachelriess
Journal:  Eur Radiol       Date:  2013-03-22       Impact factor: 5.315

6.  Can MRI accurately detect pilon articular malreduction? A quantitative comparison between CT and 3T MRI bone models.

Authors:  Shairah Radzi; Constantin Edmond Dlaska; Gary Cowin; Mark Robinson; Jit Pratap; Michael Andreas Schuetz; Sanjay Mishra; Beat Schmutz
Journal:  Quant Imaging Med Surg       Date:  2016-12

7.  Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy.

Authors:  Hua Li; Camille Noel; Haijian Chen; H Harold Li; Daniel Low; Kevin Moore; Paul Klahr; Jeff Michalski; Hiram A Gay; Wade Thorstad; Sasa Mutic
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

8.  Metal Artifact Suppression in Dental Cone Beam Computed Tomography Images Using Image Processing Techniques.

Authors:  Masoumeh Johari; Milad Abdollahzadeh; Farzad Esmaeili; Vahideh Sakhamanesh
Journal:  J Med Signals Sens       Date:  2018 Jan-Mar
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.