Literature DB >> 21222141

Corrosion study of single crystal Ni-Mn-Ga alloy and Tb0.27Dy0.73Fe1.95 alloy for the design of new medical microdevices.

Pierre Pouponneau1, Oumarou Savadogo, Teko Napporn, L'Hocine Yahia, Sylvain Martel.   

Abstract

Once placed in a magnetic field, smart magnetic materials (SMM) change their shape, which could be use for the development of smaller minimally invasive surgery devices activated by magnetic field. However, the potential degradation and release of cytotoxic ions by SMM corrosion has to be determined. This paper evaluates the corrosion resistance of two SMM: a single crystal Ni-Mn-Ga alloy and Tb(0.27)Dy(0.73)Fe(1.95) alloy. Ni-Mn-Ga alloy displayed a corrosion potential (E (corr)) of -0.58 V/SCE and a corrosion current density (i (corr)) of 0.43 μA/cm(2). During the corrosion assay, Ni-Mn-Ga sample surface was partially protected; local pits were formed on 20% of the surface and nickel ions were mainly found in the electrolyte. Tb(0.27)Dy(0.73)Fe(1.95) alloy exhibited poor corrosion properties such as E (corr) of -0.87 V/SCE and i (corr) of 5.90 μA/cm(2). During the corrosion test, this alloy was continuously degraded, its surface was impaired by pits and cracks extensively and a high amount of iron ions was measured in the electrolyte. These alloys exhibited low corrosion parameters and a selective degradation in the electrolyte. They could only be used for medical applications if they are coated with high strain biocompatible materials or embedded in composites to prevent direct contact with physiological fluids.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21222141     DOI: 10.1007/s10856-010-4206-2

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  12 in total

1.  Robotics and telemanipulation technologies for endoscopic surgery. A review of the ARTEMIS project. Advanced Robotic Telemanipulator for Minimally Invasive Surgery.

Authors:  M O Schurr; G Buess; B Neisius; U Voges
Journal:  Surg Endosc       Date:  2000-04       Impact factor: 4.584

2.  The durability of parylene coatings on neodymium-iron-boron magnets.

Authors:  J H Noar; A Wahab; R D Evans; A G Wojcik
Journal:  Eur J Orthod       Date:  1999-12       Impact factor: 3.075

Review 3.  Robotic surgery: a current perspective.

Authors:  Anthony R Lanfranco; Andres E Castellanos; Jaydev P Desai; William C Meyers
Journal:  Ann Surg       Date:  2004-01       Impact factor: 12.969

4.  A comparative study of the in vitro corrosion behavior and cytotoxicity of a superferritic stainless steel, a Ti-13Nb-13Zr alloy, and an austenitic stainless steel in Hank's solution.

Authors:  S L Assis; S O Rogero; R A Antunes; A F Padilha; I Costa
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2005-04       Impact factor: 3.368

5.  In vivo and in vitro characterization of poly(styrene-b-isobutylene-b-styrene) copolymer stent coatings for biostability, vascular compatibility and mechanical integrity.

Authors:  Fred Strickler; Robert Richard; Sharon McFadden; Jeff Lindquist; Marlene C Schwarz; Rudolf Faust; Gregory J Wilson; Mark Boden
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

6.  Magnetic nanoparticles encapsulated into biodegradable microparticles steered with an upgraded magnetic resonance imaging system for tumor chemoembolization.

Authors:  Pierre Pouponneau; Jean-Christophe Leroux; Sylvain Martel
Journal:  Biomaterials       Date:  2009-08-19       Impact factor: 12.479

Review 7.  Nickel.

Authors:  D G Barceloux
Journal:  J Toxicol Clin Toxicol       Date:  1999

8.  Corrosion study of iron-cobalt alloys for MRI-based propulsion embedded in untethered microdevices operating in the vascular network.

Authors:  Pierre Pouponneau; Oumarou Savadogo; Teko Napporn; L'hocine Yahia; Sylvain Martel
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2010-04       Impact factor: 3.368

9.  Biocorrosion investigation of two shape memory nickel based alloys: Ni-Mn-Ga and thin film NiTi.

Authors:  L L Stepan; D S Levi; E Gans; K P Mohanchandra; M Ujihara; G P Carman
Journal:  J Biomed Mater Res A       Date:  2007-09-01       Impact factor: 4.396

10.  Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks' solution.

Authors:  O Cissé; O Savadogo; M Wu; L'H Yahia
Journal:  J Biomed Mater Res       Date:  2002-09-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.