Literature DB >> 2122197

Doses on the central axes of narrow 6-MV x-ray beams.

B E Bjärngard1, J S Tsai, R K Rice.   

Abstract

The absorbed doses on the central axes of narrow beams (radii 0.07-2.5 cm) of 6-MV x rays have been studied by experiments and Monte Carlo simulations. The measurements were made in a geometry used for irradiation of intracranial lesions. For radii less than 1.0 cm the dose on the central axis is progressively reduced due to electron disequilibrium. This leads to measurement artifacts when the detector is too large, as was readily observed with ionization chambers. Radiographic and radiochromic films were used with densitometric evaluation to provide the resolution necessary to measure absorbed doses for the narrowest beams. The contribution by phantom-scattered photons is significant even at small field sizes, and scatter factors were determined from the experimental results. Photons scattered by the auxiliary collimator did not add appreciably to the dose on the central axis. The data were used to characterize the dose-to-kerma ratio as a function of beam radius. Differences between experimental results and those from Monte Carlo calculations were observed.

Entities:  

Mesh:

Year:  1990        PMID: 2122197     DOI: 10.1118/1.596475

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Development of a stereotactic device for gamma knife irradiation of small animals.

Authors:  Hyun-Tai Chung; Young Seob Chung; Dong Gyu Kim; Sun Ha Paek; Keun-Tae Cho
Journal:  J Korean Neurosurg Soc       Date:  2008-01-20

2.  Study of efficiency in five-field and field-by-field intensity modulated radiation therapy (IMRT) plan using DOSXYZnrc Monte Carlo code.

Authors:  Sitti Yani; Indra Budiansah; Mohamad Fahdillah Rhani; Freddy Haryanto
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-27

3.  Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system.

Authors:  Corey Clift; Andrew Thomas; John Adamovics; Zheng Chang; Indra Das; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-02-04       Impact factor: 3.609

4.  Monte carlo simulation of bony heterogeneity effects on dose profile for small irradiation field in radiotherapy.

Authors:  Simone C Cardoso; Victor Gabriel L Alves; Luiz Antonio R da Rosa; Luciana T Campos; Delano V S Batista; Alessandro Facure
Journal:  PLoS One       Date:  2010-05-03       Impact factor: 3.240

5.  Feasibility of using glass-bead thermoluminescent dosimeters for radiotherapy treatment plan verification.

Authors:  Shakardokht M Jafari; Tom J Jordan; Gail Distefano; David A Bradley; Nicholas M Spyrou; Andrew Nisbet; Catharine H Clark
Journal:  Br J Radiol       Date:  2015-08-10       Impact factor: 3.039

6.  Quality and safety considerations in stereotactic radiosurgery and stereotactic body radiation therapy: Executive summary.

Authors:  Timothy D Solberg; James M Balter; Stanley H Benedict; Benedick A Fraass; Brian Kavanagh; Curtis Miyamoto; Todd Pawlicki; Louis Potters; Yoshiya Yamada
Journal:  Pract Radiat Oncol       Date:  2011-09-15

7.  Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT.

Authors:  Jinkoo Kim; Ning Wen; Jian-Yue Jin; Nicole Walls; Sangroh Kim; Haisen Li; Lei Ren; Yimei Huang; Anthony Doemer; Kathleen Faber; Tina Kunkel; Ahssan Balawi; Kimberly Garbarino; Kenneth Levin; Samir Patel; Munther Ajlouni; Brett Miller; Teamor Nurushev; Calvin Huntzinger; Raymond Schulz; Indrin J Chetty; Benjamin Movsas; Samuel Ryu
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

8.  Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films.

Authors:  Sharifeh A Dini; Rafiq A Koona; John R Ashburn; Ali S Meigoonia
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

9.  Percentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry.

Authors:  L A R da Rosa; S C Cardoso; L T Campos; V G L Alves; D V S Batista; A Facure
Journal:  J Appl Clin Med Phys       Date:  2010-01-28       Impact factor: 2.102

10.  Commissioning and initial stereotactic ablative radiotherapy experience with Vero.

Authors:  Timothy D Solberg; Paul M Medin; Ezequiel Ramirez; Chuxiong Ding; Ryan D Foster; John Yordy
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.