Analysis of clusterin glycoforms in the urine of BSE-infected Fleckvieh-Simmental cows.

Lise Lamoureux1, Sharon L R Simon, Margot Plews, Michael Stobart, Martin Groschup, Stefanie Czub, Catherine Graham, J David Knox.   

Abstract

Currently approved tests for bovine spongiform encephalopathy (BSE) monitoring in cattle are based on the detection of the disease-related isoform of the prion protein in brain tissue and consequently are only suitable for postmortem diagnosis. Previously, to meet the demand for an antemortem test based on a matrix that would permit easy access and repeated sampling, two-dimensional differential gel electrophoresis (2D-DIGE) was used to perform an unbiased screen of bovine urine. Data demonstrated the altered abundance of particular isoforms of the multifunctional glycoprotein clusterin in urine samples obtained from BSE-infected and age-matched Fleckvieh-Simmental cattle. Unfortunately, the use of particular isoforms of a relatively abundant urine protein such as clusterin for diagnosis faces many of the same challenges encountered in tests based on PrP(d) detection. In both instances the specific detection of the marker protein is complicated by the high background levels of proteins with identical amino acid sequences, but lacking the disease-specific posttranslational modifications or configuration. The goal of the current study was to define the distinguishing characteristics of the clusterin isoforms observed. Biochemical and mass spectrometry analyses in combination with the generation of bovine clusterin subunit-specific antibodies enabled us to demonstrate that it was β-subunits of clusterin possessing N-linked glycans of complex structure that exhibited differential abundance in response to BSE infection. The charateristic highly glycosylated clusterin β-subunit was detectable as early as 16 mo post infection (mpi) by one-dimensional (1D) Western blot analysis of urine obtained from BSE-infected cattle.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21218342     DOI: 10.1080/15287394.2011.529063

Source DB:  PubMed          Journal:  J Toxicol Environ Health A        ISSN: 0098-4108


  2 in total

1.  Factors affecting the accuracy of urine-based biomarkers of BSE.

Authors:  Margot Plews; Lise Lamoureux; Sharon Lr Simon; Catherine Graham; Viola Ruddat; Stefanie Czub; J David Knox
Journal:  Proteome Sci       Date:  2011-02-07       Impact factor: 2.480

Review 2.  The Influence of Clusterin Glycosylation Variability on Selected Pathophysiological Processes in the Human Body.

Authors:  Ewa Janiszewska; Agnieszka Kmieciak; Monika Kacperczyk; Aleksandra Witkowska; Ewa Maria Kratz
Journal:  Oxid Med Cell Longev       Date:  2022-08-28       Impact factor: 7.310

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.