Literature DB >> 21217041

Comparison of the vanadate oxidase method with the diazo method for serum bilirubin determination in dog, monkey, and rat.

Mehrdad Ameri1, Henry Schnaars, John Sibley, David Honor.   

Abstract

The most widely used method for bilirubin concentration determination is the diazo method, which measures the color of azobilirubin. The vanadate oxidase method is based on oxidation of bilirubin to biliverdin by vanadate. The objective of this study was to compare total and direct bilirubin concentration ([Bt] and [Bd], respectively) determined by the diazo and vanadate oxidase methods in pooled serum samples from dogs, monkeys, and rats spiked with panels of different concentrations of bilirubin standards. Pooled serum samples from 40 dogs, 40 monkeys, and 60 rats were spiked with either ditaurine conjugates of bilirubin or a standard reference material. The results obtained from both assays were compared using Deming regression analysis. The intra- and interassay precision, expressed as a percentage of the coefficient of variation (%CV), was determined for [Bt] and [Bd], and the mean percentage of recovery was calculated. The vanadate oxidase method displayed an excellent correlation (r  =  0.99-1.00) with the diazo method. Using Deming regression, there were minimal negative or positive constant and proportional biases for [Bt] and [Bd]. The precision studies revealed that the vanadate oxidase method has comparable between-run and within-run CVs to those of the diazo method. The recovery study demonstrated that the diazo method more closely approximates the expected values of [Bt]. In conclusion, the vanadate oxidase method is a simple and rapid method that can be employed as an alternative to the diazo method when interfering substances are present in the serum samples of dog, monkey, and rat.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21217041     DOI: 10.1177/104063871102300121

Source DB:  PubMed          Journal:  J Vet Diagn Invest        ISSN: 1040-6387            Impact factor:   1.279


  4 in total

1.  Paper-based device for the colorimetric assay of bilirubin based on in-situ formation of gold nanoparticles.

Authors:  Resmi P Edachana; Abishek Kumaresan; Vidhya Balasubramanian; Ramachandran Thiagarajan; Bipin G Nair; Satheesh Babu Thekkedath Gopalakrishnan
Journal:  Mikrochim Acta       Date:  2019-12-17       Impact factor: 5.833

2.  Newborns bilirubin concentration determined by different methods in relation to hematocrit and albumin level.

Authors:  Joanna Berska; Jolanta Bugajska; Krystyna Sztefko
Journal:  J Med Biochem       Date:  2020-01-23       Impact factor: 3.402

3.  Efficient detection of a biomarker for infant jaundice by a europium(iii)-organic framework luminescence sensor.

Authors:  Ping Xu; Han-Wen Yang; Jia-Li Shi; Bo Ding; Xiao-Jun Zhao; En-Cui Yang
Journal:  RSC Adv       Date:  2019-11-19       Impact factor: 4.036

4.  Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory.

Authors:  Neha Dhungana; Cory Morris; Matthew D Krasowski
Journal:  Pract Lab Med       Date:  2017-05-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.