Literature DB >> 21216796

Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma.

Kaweh Mansouri1, Tarek Shaarawy.   

Abstract

The authors report their initial clinical results with a novel wireless ocular telemetry sensor (OTS) (Sensimed AG, Switzerland) for continuous intraocular pressure (IOP) monitoring in patients with open angle glaucoma. This was a prospective, observational cohort of 15 patients. The OTS is a disposable silicone contact lens with an embedded micro-electromechanical system, which measures changes in corneal curvature induced by variations in IOP. An antenna, mounted around the eye, receives the data, which are then transmitted to a recorder. A signal was recorded in all patients. Thirteen (87%) patients completed 24-h IOP monitoring: one patient discontinued IOP monitoring due to device intolerance, and incomplete recordings were obtained in a second patient due to technical device malfunction. In 9/13 (69%) patients, the highest signals were recorded during the nocturnal period. No serious adverse events were recorded. The OTS shows good safety and functionality to monitor IOP fluctuations in patients over 24 h. This technology has the potential to provide hitherto unobtainable data on the chronobiology of IOP, possibly leading to improved care of glaucoma patients.

Entities:  

Mesh:

Year:  2011        PMID: 21216796     DOI: 10.1136/bjo.2010.192922

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  58 in total

1.  Reply to: 'TLP: a premature concept'.

Authors:  I Januleviciene; L Siaudvytyte; A Daveckaite; A Ragauskas; B Siesky; A Harris
Journal:  Eye (Lond)       Date:  2015-11-13       Impact factor: 3.775

Review 2.  Microelectromechanical systems and nephrology: the next frontier in renal replacement technology.

Authors:  Steven Kim; Shuvo Roy
Journal:  Adv Chronic Kidney Dis       Date:  2013-11       Impact factor: 3.620

3.  Effect of glaucoma medications on 24-hour intraocular pressure-related patterns using a contact lens sensor.

Authors:  Kaweh Mansouri; Felipe A Medeiros; Robert N Weinreb
Journal:  Clin Exp Ophthalmol       Date:  2015-08-16       Impact factor: 4.207

4.  24-hour IOP telemetry in the nonhuman primate: implant system performance and initial characterization of IOP at multiple timescales.

Authors:  J Crawford Downs; Claude F Burgoyne; William P Seigfreid; Juan F Reynaud; Nicholas G Strouthidis; Verney Sallee
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-09-21       Impact factor: 4.799

5.  Relationship between intraocular pressure, anterior chamber depth and lens thickness in primary open-angle glaucoma patients.

Authors:  Bolajoko A Adewara; Bernice O Adegbehingbe; Oluwatoyin H Onakpoya; Chidi G Ihemedu
Journal:  Int Ophthalmol       Date:  2017-03-13       Impact factor: 2.031

6.  Positional independence of optic nerve head and retinal nerve fiber layer thickness measurements with spectral-domain optical coherence tomography.

Authors:  Kaweh Mansouri; John H K Liu; Ali Tafreshi; Felipe A Medeiros; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2012-07-19       Impact factor: 5.258

7.  Fabry-Pérot optical sensor and portable detector for monitoring high-resolution ocular hemodynamics.

Authors:  Jeong Oen Lee; Vinayak Narasimhan; Ashwin Balakrishna; Marcus R Smith; Juan Du; David Sretavan; Hyuck Choo
Journal:  IEEE Photonics Technol Lett       Date:  2019-02-01       Impact factor: 2.468

8.  Real-Time In Vivo Intraocular Pressure Monitoring using an Optomechanical Implant and an Artificial Neural Network.

Authors:  Kun Ho Kim; Jeong Oen Lee; Juan Du; David Sretavan; Hyuck Choo
Journal:  IEEE Sens J       Date:  2017-10-05       Impact factor: 3.301

9.  Can a contact lens sensor predict the success of trabectome surgery?

Authors:  Naoki Tojo; Atsushi Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-03       Impact factor: 3.117

Review 10.  IOP telemetry in the nonhuman primate.

Authors:  J Crawford Downs
Journal:  Exp Eye Res       Date:  2015-07-26       Impact factor: 3.467

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.