Literature DB >> 21215861

Predicting percent composition of blends of biodiesel and conventional diesel using gas chromatography-mass spectrometry, comprehensive two-dimensional gas chromatography-mass spectrometry, and partial least squares analysis.

Karisa M Pierce1, Stephen P Schale.   

Abstract

The percent composition of blends of biodiesel and conventional diesel from a variety of retail sources were modeled and predicted using partial least squares (PLS) analysis applied to gas chromatography-total-ion-current mass spectrometry (GC-TIC), gas chromatography-mass spectrometry (GC-MS), comprehensive two-dimensional gas chromatography-total-ion-current mass spectrometry (GCxGC-TIC) and comprehensive two-dimensional gas chromatography-mass spectrometry (GCxGC-MS) separations of the blends. In all four cases, the PLS predictions for a test set of chromatograms were plotted versus the actual blend percent composition. The GC-TIC plot produced a best-fit line with slope=0.773 and y-intercept=2.89, and the average percent error of prediction was 12.0%. The GC-MS plot produced a best-fit line with slope=0.864 and y-intercept=1.72, and the average percent error of prediction was improved to 6.89%. The GCxGC-TIC plot produced a best-fit line with slope=0.983 and y-intercept=0.680, and the average percent error was slightly improved to 6.16%. The GCxGC-MS plot produced a best-fit line with slope=0.980 and y-intercept=0.620, and the average percent error was 6.12%. The GCxGC models performed best presumably due to the multidimensional advantage of higher dimensional instrumentation providing more chemical selectivity. All the PLS models used 3 latent variables. The chemical components that differentiate the blend percent compositions are reported. Copyright Â
© 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21215861     DOI: 10.1016/j.talanta.2010.07.084

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Unsupervised classification of petroleum Certified Reference Materials and other fuels by chemometric analysis of gas chromatography-mass spectrometry data.

Authors:  Werickson Fortunato de Carvalho Rocha; Michele M Schantz; David A Sheen; Pamela M Chu; Katrice A Lippa
Journal:  Fuel (Lond)       Date:  2017-02-23       Impact factor: 6.609

2.  Metabolic Exchange with Non-Alkane-Consuming Pseudomonas stutzeri SLG510A3-8 Improves n-Alkane Biodegradation by the Alkane Degrader Dietzia sp. Strain DQ12-45-1b.

Authors:  Bing Hu; Miaoxiao Wang; Shuang Geng; Liqun Wen; Mengdi Wu; Yong Nie; Yue-Qin Tang; Xiao-Lei Wu
Journal:  Appl Environ Microbiol       Date:  2020-04-01       Impact factor: 4.792

3.  Two-Dimensional Gas Chromatographic and Mass Spectrometric Characterization of Lipid-Rich Biological Matrices-Application to Human Cerumen (Earwax).

Authors:  Allix M Coon; A John Dane; Gavin Setzen; Robert B Cody; Rabi A Musah
Journal:  ACS Omega       Date:  2021-12-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.