Literature DB >> 21214712

Alternating one lung ventilation using a double lumen endobronchial tube and providing CPAP to the non-ventilated lung in a dog.

Chiara Adami1, Shannon Axiak, Ulrich Rytz, Claudia Spadavecchia.   

Abstract

INTRODUCTION: This case report describes the anaesthetic management of exploratory thoracoscopy and alternating one lung ventilation (OLV) in a dog with a pulmonary bulla, and the application of continuous positive airway pressure (CPAP) to the non-ventilated lung for preventing and treating hypoxia. CASE HISTORY: A 6-year-old, male castrated Border collie was scheduled for exploratory thoracoscopy to investigate spontaneous pnemothorax that had not resolved with repeated suction. Specific requirements for the thoracoscopy were alternating OLV to allow the surgical access to the right middle lobe and its removal, and the examination of the left hemithorax to rule out the presence of other lesions. DIAGNOSIS AND MANAGEMENT: Selective lung ventilation was performed with a double lumen endobronchial tube (DLT), inserted under endoscopic guidance. After a short period of two lung ventilation during preparation of the surgical field, alternating OLV was performed, combining CPAP, provided to the non-ventilated lung via a Mapleson D breathing system, and positive end-expiratory pressure (PEEP) applied to the ventilated lung. Left OLV occurred first and resection of the right middle pulmonary lobe was successfully performed; right OLV followed to allow the examination of the left hemithorax. DISCUSSION AND
CONCLUSIONS: The combination of CPAP and PEEP resulted in a satisfactory intra-operative management of hypoxemia. Alternating OLV can be performed successfully by using a DLT. CPAP, commonly employed in human medicine, should be considered an important tool in the anaesthetic management of OLV in small animals.
© 2011 The Authors. Veterinary Anaesthesia and Analgesia © 2011 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.

Entities:  

Mesh:

Year:  2011        PMID: 21214712     DOI: 10.1111/j.1467-2995.2010.00586.x

Source DB:  PubMed          Journal:  Vet Anaesth Analg        ISSN: 1467-2987            Impact factor:   1.648


  2 in total

1.  A novel method for right one-lung ventilation modeling in rabbits.

Authors:  Ze-Ping Xu; Lian-Bing Gu; Qing-Ming Bian; Peng-Yi Li; Li-Jun Wang; Xiao-Xiang Chen; Jing-Yuan Zhang
Journal:  Exp Ther Med       Date:  2016-06-07       Impact factor: 2.447

2.  One-lung ventilation with use of a double lumen tube in two dogs; when right might be wrong.

Authors:  Donna Maree White; Alastair R Mair; Fernando Martinez-Taboada
Journal:  Open Vet J       Date:  2018-06-26
  2 in total