Literature DB >> 21213333

Molecular imaging of vulnerable plaques in rabbits using contrast-enhanced ultrasound targeting to vascular endothelial growth factor receptor-2.

Hong Liu1, Xiang Wang, Kai-Bing Tan, Ping Liu, Zhong-Xiong Zhuo, Zheng Liu, Xing Hua, Qin-Qiang Zhuo, Hong-Mei Xia, Yun-Hua Gao.   

Abstract

PURPOSE: Increased neovascularization has been identified as a feature of atherosclerotic plaque vulnerability and can be traced by microbubble ultrasound contrast agents (UCA). We investigated the relationship between retention of a vascular endothelial growth factor receptor 2 (VEGFR-2) targeted UCA and VEGFR-2 expression in a vulnerable plaque model in rabbits.
METHODS: Microbubbles targeting to VEGFR-2 were prepared by conjugation of biotinylated microbubbles with biotinylated VEGFR-2 antibody via streptavidin. Vulnerability was created by delivering recombinant p53 adenovirus to atherosclerotic plaques obtained in abdominal aorta by a high cholesterol diet and balloon endothelial injury. Twelve week later, the average video intensity of pre- and postcontrast ultrasound images was measured. VEGFR-2 expression and vascular density were quantified by immunohistochemical staining.
RESULTS: Retention of targeted UCA in plaques was higher than that of nontargeted UCA (144 ± 18 dB versus 107 ± 9 dB; Z= -3.984, p = 0.000). VEGFR-2 expression was correlated with video intensity of targeted (r(2) = 0.78, p = 0.001), but not of nontargeted, UCA (r(2) = 0.17, p ≥ 0.05).
CONCLUSIONS: The magnitude of the sonographic signal from retained VEGFR-2 targeted UCA correlates with VEGFR-2 expression. These results validate the use of targeted UCA for sonographic imaging of vulnerable abdominal artery plaques in rabbits.
Copyright © 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21213333     DOI: 10.1002/jcu.20759

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  10 in total

1.  Selective Imaging of Vascular Endothelial Growth Factor Receptor-1 and Receptor-2 in Atherosclerotic Lesions in Diabetic and Non-diabetic ApoE-/- Mice.

Authors:  Yared Tekabe; Lynne L Johnson; Krissy Rodriquez; Qing Li; Marina Backer; Joseph M Backer
Journal:  Mol Imaging Biol       Date:  2018-02       Impact factor: 3.488

Review 2.  PET imaging of aortic atherosclerosis: Is combined imaging of plaque anatomy and function an amaranthine quest or conceivable reality?

Authors:  Gary R Small; Terrence D Ruddy
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

3.  Diagnosis of Atherosclerotic Plaques Using Vascular Endothelial Growth Factor Receptor-2 Targeting Antibody Nano-microbubble as Ultrasound Contrast Agent.

Authors:  Yi Wang; Yujin Feng; Xiaoyun Yang; Wengang Wang; Yueheng Wang
Journal:  Comput Math Methods Med       Date:  2022-05-05       Impact factor: 2.809

4.  Assessment of atherosclerotic plaques in the rabbit abdominal aorta with interleukin-8 monoclonal antibody-targeted ultrasound microbubbles.

Authors:  Yongping Lu; Jia Wei; Qinghua Shao; Yueyue Tang; Yanling Huang; Huali Zhang; Wei Yang; Zhi Jing
Journal:  Mol Biol Rep       Date:  2013-01-05       Impact factor: 2.316

5.  Imaging key biomarkers of tumor angiogenesis.

Authors:  Marina V Backer; Joseph M Backer
Journal:  Theranostics       Date:  2012-05-17       Impact factor: 11.556

6.  Detection of high-risk atherosclerotic plaques with ultrasound molecular imaging of glycoprotein IIb/IIIa receptor on activated platelets.

Authors:  Shengcun Guo; Shuxin Shen; Junfen Wang; He Wang; Meiyu Li; Ying Liu; Fanfan Hou; Yulin Liao; Jianping Bin
Journal:  Theranostics       Date:  2015-02-05       Impact factor: 11.556

7.  Microbubbles coupled to methotrexate-loaded liposomes for ultrasound-mediated delivery of methotrexate across the blood-brain barrier.

Authors:  Xiang Wang; Ping Liu; Weixiao Yang; Lu Li; Peijing Li; Zheng Liu; Zhongxiong Zhuo; Yunhua Gao
Journal:  Int J Nanomedicine       Date:  2014-10-23

Review 8.  Contrast-enhanced ultrasound: clinical applications in patients with atherosclerosis.

Authors:  Arend F L Schinkel; Mathias Kaspar; Daniel Staub
Journal:  Int J Cardiovasc Imaging       Date:  2015-07-24       Impact factor: 2.357

9.  Accurate and continuous ultrasonography evaluation of small diameter vascular prostheses in vivo.

Authors:  Jing Shi; Jialing Zhang; Meng Yin; Qian Wang; Jun Du
Journal:  Exp Ther Med       Date:  2018-02-26       Impact factor: 2.447

10.  The immunologic injury composite with balloon injury leads to dyslipidemia: a robust rabbit model of human atherosclerosis and vulnerable plaque.

Authors:  Guangyin Zhang; Ming Li; Liangjun Li; Yingzhi Xu; Peng Li; Cui Yang; Yanan Zhou; Junping Zhang
Journal:  J Biomed Biotechnol       Date:  2012-09-04
  10 in total