BACKGROUND: The Vertical Expandable Prosthetic Titanium Rib (VEPTR™; Synthes North America, West Chester, PA) reportedly controls spinal deformity associated with constrictive chest wall conditions. QUESTIONS/PURPOSES: We asked whether spine-to-spine constructs using VEPTR™ instrumentation in combination with standard spinal instrumentation could be deployed to salvage failed rib-to-spine constructs used originally in patients with constricted chest walls and to primarily treat progressive spinal deformity without chest wall abnormalities. PATIENTS AND METHODS: Fifty patients were treated with VEPTR™ constructs for thoracic insufficiency syndrome at our center between 2001 and 2007. Fourteen of these 50 patients had placement of a spine-to-spine construct using a VEPTR™ implant in combination with standard spinal implants and are the subject of this retrospective review. Five had prior rib-based VEPTR™ or growing implants with an average of two failures before this surgery. Radiographic variables, preceding treatment, complications, and changes in ambulatory status, were recorded. The minimum followup was 2 years (mean, 35 months; range, 2-4 years). RESULTS: After an average of five expansions in these 14 patients, positive changes were recorded for Cobb angle, T1-S1 height, sagittal balance, and space available for the lung. Complications included two rod fractures, two superficial infections, and one deep infection with rod removal. CONCLUSIONS: VEPTR™ instrumentation as a spine-to-spine growing-rod construct demonstrated ease of implantation and expansion, with complication rates similar to other reported devices. This study suggests growing constructs using VEPTR™ can be used with relatively few complications and extends the potential uses of this instrumentation system.
BACKGROUND: The Vertical Expandable Prosthetic Titanium Rib (VEPTR™; Synthes North America, West Chester, PA) reportedly controls spinal deformity associated with constrictive chest wall conditions. QUESTIONS/PURPOSES: We asked whether spine-to-spine constructs using VEPTR™ instrumentation in combination with standard spinal instrumentation could be deployed to salvage failed rib-to-spine constructs used originally in patients with constricted chest walls and to primarily treat progressive spinal deformity without chest wall abnormalities. PATIENTS AND METHODS: Fifty patients were treated with VEPTR™ constructs for thoracic insufficiency syndrome at our center between 2001 and 2007. Fourteen of these 50 patients had placement of a spine-to-spine construct using a VEPTR™ implant in combination with standard spinal implants and are the subject of this retrospective review. Five had prior rib-based VEPTR™ or growing implants with an average of two failures before this surgery. Radiographic variables, preceding treatment, complications, and changes in ambulatory status, were recorded. The minimum followup was 2 years (mean, 35 months; range, 2-4 years). RESULTS: After an average of five expansions in these 14 patients, positive changes were recorded for Cobb angle, T1-S1 height, sagittal balance, and space available for the lung. Complications included two rod fractures, two superficial infections, and one deep infection with rod removal. CONCLUSIONS: VEPTR™ instrumentation as a spine-to-spine growing-rod construct demonstrated ease of implantation and expansion, with complication rates similar to other reported devices. This study suggests growing constructs using VEPTR™ can be used with relatively few complications and extends the potential uses of this instrumentation system.
Authors: Robert M Campbell; Melvin D Smith; Thomas C Mayes; John A Mangos; Donna B Willey-Courand; Nusret Kose; Ricardo F Pinero; Marden E Alder; Hoa L Duong; Jennifer L Surber Journal: J Bone Joint Surg Am Date: 2003-03 Impact factor: 5.284
Authors: Behrooz A Akbarnia; David S Marks; Oheneba Boachie-Adjei; Alistair G Thompson; Marc A Asher Journal: Spine (Phila Pa 1976) Date: 2005-09-01 Impact factor: 3.468
Authors: George H Thompson; Behrooz A Akbarnia; Patricia Kostial; Connie Poe-Kochert; Douglas G Armstrong; Jeffrey Roh; Robert Lowe; Marc A Asher; David S Marks Journal: Spine (Phila Pa 1976) Date: 2005-09-15 Impact factor: 3.468
Authors: Robert M Campbell; Melvin D Smith; Thomas C Mayes; John A Mangos; Donna B Willey-Courand; Nusret Kose; Ricardo F Pinero; Marden E Alder; Hoa L Duong; Jennifer L Surber Journal: J Bone Joint Surg Am Date: 2004-08 Impact factor: 5.284