Literature DB >> 21210625

The Harris-Galante cementless THA: a 19- to 25-year follow-up study.

Shu Saito1, Takao Ishii, Sei Mori, Kunihiro Hosaka, Yasuaki Tokuhashi.   

Abstract

The goal of this study was to evaluate the long-term survivorship of primary cementless total hip arthroplasty (THA) using Harris-Galante porous I acetabular and Harris-Galante porous femoral components. From July 1985 to December 1991, we performed primary cementless THA on 76 hips (70 patients). Twenty-nine patients (31 hips) died due to causes unrelated to the THA, and 6 patients (7 hips) were lost to follow-up. Of 76 hips (70 patients) studied, 38 hips (35 patients) were available for follow-up at a mean 22.5 years (range, 19-25 years) postoperatively. Mean patient age at index procedure was 51.2 years (range, 42-65 years). Average Harris Hip Score was 40.5 points preoperatively and 85.8 points at final follow-up. No patient had an early or late postoperative deep infection. Radiographically, the acetabular component fixation was stable in all 38 hips. The femoral component was bone-ingrown in 26 hips, stable-fibrous in 10, and unstable in 2. One unstable hip required revision of the femoral component. Dissociation of the polyethylene liner occurred in 3 hips without fractures of the metal locking tines and required revision of the polyethylene liner and the articular head. A total of 4 hips had documented revision, and 1 femoral component failed radiographically. The survival rate with the endpoint defined as revision surgery and radiographic loosening was 86.8% at 22.5 years of follow-up. Mean polyethylene wear was 0.085 mm/year (range, 0.031-0.15 mm). This study found that the Harris-Galante porous I acetabular and Harris-Galante porous femoral components produce excellent long-term results. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21210625     DOI: 10.3928/01477447-20101123-08

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  5 in total

1.  The Müller self-locking cemented total hip prosthesis with polyethylene liner: After twenty years, what did they become?

Authors:  Roger Erivan; Guillaume Villatte; Youcef Reda Khelif; Bruno Pereira; Myriam Galvin; Stéphane Descamps; Stéphane Boisgard
Journal:  Int Orthop       Date:  2016-04-25       Impact factor: 3.075

2.  Long-term (20- to 25-year) results of an uncemented tapered titanium femoral component and factors affecting survivorship.

Authors:  Marcus R Streit; Moritz M Innmann; Christian Merle; Thomas Bruckner; Peter R Aldinger; Tobias Gotterbarm
Journal:  Clin Orthop Relat Res       Date:  2013-05-14       Impact factor: 4.176

Review 3.  Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Authors:  Deborah A Marshall; Karen Pykerman; Jason Werle; Diane Lorenzetti; Tracy Wasylak; Tom Noseworthy; Donald A Dick; Greg O'Connor; Aish Sundaram; Sanne Heintzbergen; Cy Frank
Journal:  Clin Orthop Relat Res       Date:  2014-04-04       Impact factor: 4.176

4.  Average 22-Year Results of Total Hip Arthroplasty Using Harris-Galante Prosthesis in Patients under 50 Years.

Authors:  Heejae Won; Seung-Hoon Baek; Junekyu Kim; Won Kee Lee; Yeon Soo Lee; Shin-Yoon Kim
Journal:  Clin Orthop Surg       Date:  2022-03-03

5.  Prosthetic femoral head erosion through an acetabular component treated with revision and implant preservation.

Authors:  Mark Daniel Kohn; Navin Fernando
Journal:  Arthroplast Today       Date:  2020-01-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.