Literature DB >> 21206323

Microcatheter neck bridging and incorporated branch vessel protection for coil embolization of a wide-neck ruptured aneurysm: technical case report.

Ajeet Gordhan1.   

Abstract

BACKGROUND AND IMPORTANCE: A novel technique in which microcatheter neck bridging of a ruptured wide-neck posterior communicating artery aneurysm was performed by intra-aneurysmal catheter navigation into a fetal configuration posterior cerebral artery (PCA) branch vessel arising from the sac. CLINICAL
PRESENTATION: An 88-year-old woman with a Hunt and Hess grade 1 and Fisher grade 4 subarachnoid hemorrhage was identified as having a wide-neck posterior communicating artery aneurysm and an isolated fetal configuration PCA with origins from the aneurysm sac. Delivery of a bare platinum Guglielmi detachable coil within the aneurysm lumen resulted in persistent coil prolapse into the parent vessel with occlusion of the incorporated vital PCA origin. A microcatheter was then navigated through the aneurysm lumen and into the fetal configuration PCA. This was retained within the PCA with resultant aneurysm neck narrowing and branch vessel protection. A second microcatheter was placed in the aneurysm lumen for coil delivery. Complete aneurysm occlusion with patency of the PCA without coil loop prolapse into the parent vessel was achieved.
CONCLUSION: The presence of normal branch vessels arising from the dome is a limitation for endovascular techniques. To the best of our knowledge, no prior description of a dual-microcatheter technique with selective catheter placement within an important intra-aneurysmal branch vessel has been published. The vital branch vessel was protected and the wide-neck aneurysm completely occluded. Novel placement of microcatheters further expands the range of complex configuration aneurysms amenable to endovascular coiling.

Entities:  

Mesh:

Year:  2011        PMID: 21206323     DOI: 10.1227/NEU.0b013e318207819f

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  7 in total

1.  Intra-aneurysmal microcatheter looping technique for stent-assisted embolization of complex intracranial aneurysms.

Authors:  C-C Wang; N Lv; Z-Z Feng; Z-F Li; R Zhao; Q Li; J-M Liu; Q-H Huang
Journal:  Interv Neuroradiol       Date:  2015-07-15       Impact factor: 1.610

2.  Microguidewire protection of wide-necked aneurysms incorporating orifices of tortuous acute-angled vessels: a novel approach.

Authors:  Young Dae Cho; Hyun-Seung Kang; Jeong Eun Kim; Jun Hyong Ahn; Seung Chai Jung; Chang Hun Kim; Moon Hee Han
Journal:  Neuroradiology       Date:  2014-04-23       Impact factor: 2.804

3.  Modified coil protection for proper coil frame configuration in wide-necked aneurysms.

Authors:  Young Dae Cho; Jong Kook Rhim; Jeong Jin Park; Jin Pyeong Jeon; Hyun-Seung Kang; Jeong Eun Kim; Won-Sang Cho; Moon Hee Han
Journal:  Neuroradiology       Date:  2015-03-28       Impact factor: 2.804

4.  Coil protection using small helical coils for wide-neck intracranial aneurysms: a novel approach.

Authors:  Y D Cho; J Y Lee; J H Seo; S J Lee; H-S Kang; J E Kim; O-K Kwon; Y J Son; M H Han
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-14       Impact factor: 3.825

5.  Parent Artery Complex Coil Protection for Side-Branched Wide-Neck Aneurysms.

Authors:  Keisuke Sato; Hiroshi Aoki; Shinya Jinguji; Hiroki Seto; Tsutomu Kobayashi
Journal:  Neurointervention       Date:  2022-06-20

6.  Microcatheter looping facilitates access to both the acutely angled parent artery and cerebral aneurysms for effective embolization.

Authors:  Cong-Hui Li; Jian-Ya Ye; Xian-Hui Su; Lei Yang; Dong-Liang Zhang; Bo Zhang; Er-Wei Zhang; Yong-Feng Han; Song-Tao Yang; Bu-Lang Gao
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

7.  Coil embolization in precommunicating (A1) segment aneurysms of anterior cerebral artery.

Authors:  Young Dae Cho; Jun Hyong Ahn; Seung Chai Jung; Chang Hun Kim; Hyun-Seung Kang; Jeong Eun Kim; Young Je Son; Moon Hee Han
Journal:  Neuroradiology       Date:  2014-01-26       Impact factor: 2.804

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.