Literature DB >> 2120467

ABGs and arterial lines: the relationship to unnecessarily drawn arterial blood gas samples.

F F Muakkassa1, R Rutledge, S M Fakhry, A A Meyer, G F Sheldon.   

Abstract

Arterial blood gas measurements (ABGs) are the most common tests ordered in an ICU. ABG utilization in a surgical ICU over a 1-year period (September 1, 1987-October 31, 1988) was evaluated to identify factors that might help reduce overutilization. A total of 842 admissions comprising 2,381 patient days were reviewed. ABGs were the most commonly ordered test (mean of 4.8/patient/day). Patients with arterial lines (A-lines) had more ABGs drawn than those who did not regardless of the value of PaO2 (p less than 0.01), PaCO2 (p less than 0.01 except for PaCO2 greater than 55), APACHE II score (p less than 0.01), use of ventilators (p less than 0.01), pulse oximeters (p less than 0.01), or a combination of the last two (p less than 0.01). Multivariate analysis demonstrated that the presence of an A-line was the most powerful predictor of the number of ABGs drawn per patient (p less than 0.0001) independent of all other measures of the patient's clinical status such as the use of ventilators, oximeters, and values of PaO2, PaCO2, or the APACHE II score. This suggests that ABGs are being drawn unnecessarily simply because of the presence of an A-line. To reduce the number of ABGs drawn, a policy for specific indications for placement of A-lines and ABG analysis should be adopted.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2120467

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  8 in total

1.  A computer based intervention on the appropriate use of arterial blood gas.

Authors:  P Bansal; D Aronsky; D Aronsky; D Talbert; R A Miller
Journal:  Proc AMIA Symp       Date:  2001

2.  Quality improvement report: Linking guideline to regular feedback to increase appropriate requests for clinical tests: blood gas analysis in intensive care.

Authors:  P Merlani; P Garnerin; M Diby; M Ferring; B Ricou
Journal:  BMJ       Date:  2001-09-15

3.  Do blood tests cause anemia in hospitalized patients? The effect of diagnostic phlebotomy on hemoglobin and hematocrit levels.

Authors:  Paaladinesh Thavendiranathan; Akshay Bagai; Albert Ebidia; Allan S Detsky; Niteesh K Choudhry
Journal:  J Gen Intern Med       Date:  2005-06       Impact factor: 5.128

4.  Clinical evaluation of a multiparameter intra-arterial blood-gas sensor.

Authors:  E Abraham; T J Gallagher; S Fink
Journal:  Intensive Care Med       Date:  1996-05       Impact factor: 17.440

5.  Continuous assessment of arterial blood gases.

Authors: 
Journal:  Crit Care       Date:  1997       Impact factor: 9.097

6.  Peripheral venous blood gas analysis: An alternative to arterial blood gas analysis for initial assessment and resuscitation in emergency and intensive care unit patients.

Authors:  Shilpi Awasthi; Raka Rani; Deepak Malviya
Journal:  Anesth Essays Res       Date:  2013 Sep-Dec

7.  Clinical Utility of Arterial Blood Gas Test in an Intensive Care Unit: An Observational Study.

Authors:  Jagadish Chandran; Carol D'Silva; Sampath Sriram; Bhuvana Krishna
Journal:  Indian J Crit Care Med       Date:  2021-02

8.  Mathematically arterialised venous blood is a stable representation of patient acid-base status at steady state following acute transient changes in ventilation.

Authors:  Lisha Shastri; Søren Kjærgaard; Peter Søndergaard Thyrrestrup; Stephen Edward Rees; Lars Pilegaard Thomsen
Journal:  J Clin Monit Comput       Date:  2021-10-13       Impact factor: 1.977

  8 in total