Literature DB >> 21203701

Cytotoxicity of latex and non-latex orthodontic elastomeric ligatures on L929 mouse fibroblasts.

Rogério Lacerda dos Santos1, Matheus Melo Pithon, Fernanda Otaviano Martins, Maria Teresa Villela Romanos, Antônio Carlos de Oliveira Ruellas.   

Abstract

This study investigated the cytotoxicity exists between latex and non-latex Orthodontic elastomeric ligatures. Six elastomeric ligatures (1 latex, 2 latex-free and 3 polyurethane) from different manufacturers were divided into 6 groups of 15 elastics each: A (Latex-free, American Orthodontics), M (Polyurethane, Morelli), G (Polyurethane,GAC International), Te (Polyurethane, Tecnident), TP (Natural latex,TP Orthodontics) and U (Latex-free,3M Unitek). The cytotoxicity assay was performed using cell cultures (L929 mouse fibroblast cell line), which were subjected to the cell viability test with neutral red ("dye-uptake") at 1, 2, 3, 7 and 28 days. Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). No statistically significant differences (p>0.05) were observed between Groups M and Te in all experimental periods, except at 2 days. No significant differences (p>0.05) in cell viability were found either among Groups A, G, TP and U or between Groups M and Te at 24 h or among Groups CC, A, G, TP and U at 2 and 28 days. It may be concluded that latex-free elastomeric ligatures from American Orthodontics and Unitek trademarks induced less cell lysis compared to latex and polyurethane ligatures.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21203701     DOI: 10.1590/s0103-64402010000300005

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  5 in total

1.  Cytotoxicity of bracket identification dyes.

Authors:  Fatih Celebi; Ahmet Altun; Ali Altug Bicakci
Journal:  Angle Orthod       Date:  2018-12-28       Impact factor: 2.079

2.  Influence of different beverages on the force degradation of intermaxillary elastics: an in vitro study.

Authors:  Jorge César Borges Leão Filho; Daphine Beatriz Gallo; Regis Meller Santana; Odilon Guariza-Filho; Elisa Souza Camargo; Orlando Motohiro Tanaka
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

3.  The influence of pH levels on mechanical and biological properties of nonlatex and latex elastics.

Authors:  Rogério Lacerda Dos Santos; Matheus Melo Pithon; Maria Teresa Villela Romanos
Journal:  Angle Orthod       Date:  2011-12-09       Impact factor: 2.079

4.  Metals and Metalloids Release from Orthodontic Elastomeric and Stainless Steel Ligatures: In Vitro Risk Assessment of Human Exposure.

Authors:  Aneta Olszewska; Anetta Hanć; Danuta Barałkiewicz; Piotr Rzymski
Journal:  Biol Trace Elem Res       Date:  2019-11-04       Impact factor: 3.738

5.  The Effect of Extrinsic Factors on the Mechanical Behavior and Structure of Elastic Dental Ligatures and Chains.

Authors:  Kata Csekő; Péter Maróti; Zsuzsanna Helyes; Roland Told; Fanni Riegler; József Szalma; Zsuzsanna Gurdán
Journal:  Polymers (Basel)       Date:  2021-12-23       Impact factor: 4.329

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.