Precision requirements for cost-effective operation of analytical processes.

J O Westgard1, R W Burnett.   

Abstract

Current performance criteria for analytical methods are often based on recommendations developed many years ago. A common criterion for imprecision requires that two times the standard deviation (s) of the method be less than the allowable total error (TEa). Unfortunately, when this criterion is minimally satisfied, commonly used control procedures cannot achieve reliable detection of medically important errors. Studies of the power functions for statistical quality-control (QC) procedures show that the magnitude of medically important errors must be at least 3s to fall near the plateau of the power curves and be readily detected by current QC procedures. For methods that just meet the precision criterion 2s less than TEa, however, medically important errors will fall on the rising portion of the power curves and typically be detected less than half of the time. From a "reverse engineering" perspective, the 2s less than TEa criterion is inadequate because it does not allow for the known performance limitations (lack of sensitivity) of commonly used control procedures. A strong case can be made for using a criterion of at least '4s less than TEa, which calls for a twofold improvement in imprecision over, the current minimum requirements. This recommendation is consistent with current industrial guidelines for process capability and would lead to more reliable detection of medically important errors.

Mesh:

Year:  1990        PMID: 2119916

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  4 in total

1.  Quality leadership and quality control.

Authors:  Tony Badrick
Journal:  Clin Biochem Rev       Date:  2003-08

2.  Sigma Metric Evaluation of Drugs in a Clinical Laboratory: Importance of Choosing Appropriate Total Allowable Error and a Troubleshooting Roadmap.

Authors:  Lokesh Kumar Sharma; Rashmi Rasi Datta; Neera Sharma
Journal:  J Lab Physicians       Date:  2021-05-21

3.  Comparison between Sigma metrics in four accredited Egyptian medical laboratories in some biochemical tests: an initiative towards sigma calculation harmonization.

Authors:  Rania El Sharkawy; Sten Westgard; Ahmed M Awad; AbdelKarem Omneya I Ahmed; El Hadidi Iman; Ahmed Gaballah; Eman Shaheen
Journal:  Biochem Med (Zagreb)       Date:  2018-06-15       Impact factor: 2.313

4.  Comprehensive evaluation of the internal and external quality control to redefine analytical quality goals.

Authors:  Beatriz Varela; Gonzalo Pacheco
Journal:  Biochem Med (Zagreb)       Date:  2018-06-15       Impact factor: 2.313

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.