Methodologies for quantifying culturable, viable, and total Legionella pneumophila in indoor air.

C-W Chang1, F-C Chou.   

Abstract

UNLABELLED: Legionella pneumophila, aerosolized from numerous indoor facilities (e.g., shower heads, hot tubs, spas), may cause Pontiac fever (PF) and lethal pneumonia named Legionnaires' disease (LD) in humans. Reliable methods on quantitative exposure assessment of this bioaerosol are essential for the prevention of PF and LD. Coupled with culture, ethidium monoazide with qPCR, and qPCR assays, the collection efficiency for culturable, viable, and total L. pneumophila was assessed by means of filtration sampling (IOM with gelatin filter and cassette with polycarbonate filter) and liquid-based sampling methods (BioSampler, AGI-30, MAS-100 sampler with Tween mixture and deionized water (DW)). Results show IOM/gelatin filter was comparable to cassette/polycarbonate filter (P = 0.33) and performed greater than all of tested liquid-based methods for total cell collection. On the other hand, IOM/gelatin filter obtained greater efficiencies than cassette/polycarbonate filter by a factor of 3.8-8.6 for viable cells (P = 0.0006) and two orders of magnitude for culturable cells (P = 0.00002). Further comparison between liquid impingement and filtration methods indicates the sampling by IOM/gelatin filter, AGI-30, and BioSampler with DW were the most appropriate for viable cells, while culturable cells were collected most efficiently by BioSampler/DW with periodical replenishment during the sampling. PRACTICAL IMPLICATIONS: This study recommends the most suitable methodologies for quantifying culturable, viable, and total Legionella pneumophila in indoor air. By using appropriate sampling and analytical methods, the residents and building owners are able to obtain the reliable data and further characterize the exposure risk and/or intervention efficacy against L. pneumophila. Moreover, the adoption of suitable monitoring methods also assists the investigators to explore the sources linked to PF and LD during the outbreaks. Considering reliable microbial monitoring is fundamental for epidemiological survey and risk assessment, the present information should be taken into account in assessing L. pneumophila indoors.
© 2010 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21198889     DOI: 10.1111/j.1600-0668.2010.00701.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  6 in total

1.  Density of environmental Acanthamoeba and their responses to superheating disinfection.

Authors:  Ching-Wen Chang; Ling-Wen Lu; Chung-Long Kuo; Nien-Tzu Hung
Journal:  Parasitol Res       Date:  2013-08-10       Impact factor: 2.289

2.  Effect of selected sampling media, flow rate, and time on the sampling efficiency of a liquid impinger packed with glass beads for the collection of airborne viruses.

Authors:  Yen-Chi Chen; I-Jen Wang; Chih-Ching Cheng; Yu-Chiao Wu; Chun-Hsuan Bai; Kuo-Pin Yu
Journal:  Aerobiologia (Bologna)       Date:  2021-01-13       Impact factor: 2.376

3.  Field evaluation of personal sampling methods for multiple bioaerosols.

Authors:  Chi-Hsun Wang; Bean T Chen; Bor-Cheng Han; Andrew Chi-Yeu Liu; Po-Chen Hung; Chih-Yong Chen; Hsing Jasmine Chao
Journal:  PLoS One       Date:  2015-03-23       Impact factor: 3.240

4.  Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

Authors:  Maria Teresa Montagna; Osvalda De Giglio; Maria Luisa Cristina; Christian Napoli; Claudia Pacifico; Antonella Agodi; Tatjana Baldovin; Beatrice Casini; Maria Anna Coniglio; Marcello Mario D'Errico; Santi Antonino Delia; Maria Grazia Deriu; Marco Guida; Pasqualina Laganà; Giorgio Liguori; Matteo Moro; Ida Mura; Francesca Pennino; Gaetano Privitera; Vincenzo Romano Spica; Silvia Sembeni; Anna Maria Spagnolo; Stefano Tardivo; Ida Torre; Federica Valeriani; Roberto Albertini; Cesira Pasquarella
Journal:  Int J Environ Res Public Health       Date:  2017-06-22       Impact factor: 3.390

5.  Assessment of hygienic conditions of recreational facility restrooms: an integrated approach.

Authors:  Giuditta Fiorella Schiavano; Giulia Baldelli; Veronica Ceppetelli; Giorgio Brandi; Giulia Amagliani
Journal:  J Prev Med Hyg       Date:  2021-04-29

6.  Risk assessment of legionellosis in cardiology units.

Authors:  P Laganà; S Delia; E Avventuroso; M Casale; G Dattilo
Journal:  J Prev Med Hyg       Date:  2017-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.