Literature DB >> 21197492

The effect of splint material rigidity in implant impression techniques.

Marcelo Antonialli Del Acqua1, Alejandro Munoz Chavez, Sabrina Maria Castanharo, Marco Antonio Compagnoni, Francisco de Assis Mollo.   

Abstract

PURPOSE: This in vitro study compared the dimensional accuracy of two impression techniques: Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant-supported prostheses.
MATERIALS AND METHODS: A master cast with four parallel implant abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Two groups (D and M) were tested (n = 5). The measurement method employed was just one titanium screw tightened to the framework. Each group's measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at 3100 magnification. The results were analyzed statistically (t test).
RESULTS: The mean values of abutment/framework interface gaps were: master cast = 32 Μm (SD 2), group D =165 Μm (SD 60), and group M = 69 Μm (SD 36). There was a statistically significant difference between the D and M groups (P ⋜ .001).
CONCLUSION: Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21197492

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study.

Authors:  Sonam Gupta; Aparna Ichalangod Narayan; Dhanasekar Balakrishnan
Journal:  Int J Dent       Date:  2017-02-27

2.  The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap.

Authors:  Abolfazl Saboury; Hamid Neshandar Asli; Zahra Dalili Kajan
Journal:  J Dent (Shiraz)       Date:  2017-12

3.  Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones.

Authors:  Ioannis Kioleoglou; Argirios Pissiotis; Michalakis Konstantinos
Journal:  J Clin Exp Dent       Date:  2018-03-01

4.  To evaluate and compare the accuracy of definitive casts using various splinting methods on implant level impressions in All-on-Four treatment: An in vitro study.

Authors:  S Daya Shankar; Santosh Doddamani
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07