Literature DB >> 21193679

Comparison of three different pelvic circumferential compression devices: a biomechanical cadaver study.

S P Knops1, N W L Schep, C W Spoor, M P J M van Riel, W R Spanjersberg, G J Kleinrensink, E M M van Lieshout, P Patka, I B Schipper.   

Abstract

BACKGROUND: Pelvic circumferential compression devices are designed to stabilize the pelvic ring and reduce the volume of the pelvis following trauma. It is uncertain whether pelvic circumferential compression devices can be safely applied for all types of pelvic fractures because the effects of the devices on the reduction of fracture fragments are unknown. The aim of this study was to compare the effects of circumferential compression devices on the dynamic realignment and final reduction of the pelvic fractures as a measure of the quality of reduction.
METHODS: Three circumferential compression devices were evaluated: the Pelvic Binder, the SAM Sling, and the T-POD. In sixteen cadavers, four fracture types were generated according to the Tile classification system. Infrared retroreflective markers were fixed in the different fracture fragments of each pelvis. The circumferential compression device was applied sequentially in a randomized order with gradually increasing forces applied. Fracture fragment movement was studied with use of a three-dimensional infrared video system. Dynamic realignment and final reduction of the fracture fragments during closure of the circumferential compression devices were determined. A factorial repeated-measures analysis of variance with pairwise post hoc comparisons was performed to analyze the differences in pulling force between the circumferential compression devices.
RESULTS: In the partially stable and unstable (Tile type-B and C) pelvic fractures, all circumferential compression devices accomplished closure of the pelvic ring and consequently reduced the pelvic volume. No adverse fracture displacement (>5 mm) was observed in these fracture types. The required pulling force to attain complete reduction at the symphysis pubis varied substantially among the three different circumferential compression devices, with a mean (and standard error of the mean) of 43 ± 7 N for the T-POD, 60 ± 9 N for the Pelvic Binder, and 112 ± 10 N for the SAM Sling.
CONCLUSIONS: The Pelvic Binder, SAM Sling, and T-POD provided sufficient reduction in partially stable and unstable (Tile type-B1 and C) pelvic fractures. No undesirable overreduction was noted. The pulling force that was needed to attain complete reduction of the fracture parts varied significantly among the three devices, with the T-POD requiring the lowest pulling force for fracture reduction.

Entities:  

Mesh:

Year:  2010        PMID: 21193679     DOI: 10.2106/JBJS.J.00084

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  13 in total

Review 1.  Protocols for massive blood transfusion: when and why, and potential complications.

Authors:  E Guerado; A Medina; M I Mata; J M Galvan; M L Bertrand
Journal:  Eur J Trauma Emerg Surg       Date:  2015-12-09       Impact factor: 3.693

Review 2.  Emergency medicine techniques and the forensic autopsy.

Authors:  Claas Buschmann; Thomas Schulz; Michael Tsokos; Christian Kleber
Journal:  Forensic Sci Med Pathol       Date:  2012-08-08       Impact factor: 2.007

3.  Management of traumatic spinopelvic dissociations: review of the literature.

Authors:  W Lehmann; M Hoffmann; D Briem; L Grossterlinden; J P Petersen; M Priemel; P Pogoda; A Ruecker; J M Rueger
Journal:  Eur J Trauma Emerg Surg       Date:  2012-09-25       Impact factor: 3.693

4.  How effective are different models of pelvic binders: results of a study using a Pelvic Emergency Simulator.

Authors:  Uwe Schweigkofler; Dennis Wincheringer; Jörg Holstein; Tobias Fritz; Reinhard Hoffmann; Tim Pohlemann; Steven C Herath
Journal:  Eur J Trauma Emerg Surg       Date:  2020-05-26       Impact factor: 3.693

Review 5.  Effectiveness of non invasive external pelvic compression: a systematic review of the literature.

Authors:  Peyman Bakhshayesh; Tarek Boutefnouchet; Anna Tötterman
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-05-18       Impact factor: 2.953

Review 6.  Pelvic circumferential compression devices for prehospital management of suspected pelvic fractures: a rapid review and evidence summary for quality indicator evaluation.

Authors:  Robin Pap; Rachel McKeown; Craig Lockwood; Matthew Stephenson; Paul Simpson
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2020-07-13       Impact factor: 2.953

7.  Efficacy of extra-peritoneal pelvic packing in hemodynamically unstable pelvic fractures, a Propensity Score Analysis.

Authors:  Osvaldo Chiara; Emanuele di Fratta; Anna Mariani; Bertuzzi Michaela; Lucia Prestini; Fabrizio Sammartano; Stefania Cimbanassi
Journal:  World J Emerg Surg       Date:  2016-06-01       Impact factor: 5.469

8.  Emergency radiological examination of the externally stabilized pelvis--there is a catch to it: lessons learned from two cases with symphyseal disruption despite initial inconspicuous computed tomography.

Authors:  Jörg Bayer; Thorsten Hammer; Dirk Maier; Norbert Paul Südkamp; Oliver Hauschild
Journal:  BMC Surg       Date:  2016-03-12       Impact factor: 2.102

Review 9.  Prehospital control of life-threatening truncal and junctional haemorrhage is the ultimate challenge in optimizing trauma care; a review of treatment options and their applicability in the civilian trauma setting.

Authors:  S E van Oostendorp; E C T H Tan; L M G Geeraedts
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-09-13       Impact factor: 2.953

10.  Damage control orthopaedics: State of the art.

Authors:  Enrique Guerado; Maria Luisa Bertrand; Juan Ramon Cano; Ana María Cerván; Adolfo Galán
Journal:  World J Orthop       Date:  2019-01-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.