Literature DB >> 21193382

Development of a model osseo-magnetic link for intuitive rotational control of upper-limb prostheses.

Elliott J Rouse1, David C Nahlik, Michael A Peshkin, Todd A Kuiken.   

Abstract

The lack of proprioceptive feedback is a serious deficiency of current prosthetic control systems. The Osseo-Magnetic Link (OML) is a novel humeral or wrist rotation control system that could preserve proprioception. It utilizes a magnet implanted within the residual bone and sensors mounted in the prosthetic socket to detect magnetic field vectors and determine the bone's orientation. This allows the use of volitional bone rotation to control a prosthetic rotator. We evaluated the performance of the OML using a physical model of a transhumeral residual limb. A small Neodymium-Iron-Boron magnet was placed in a model humerus, inside a model upper arm. Four three-axis Hall-effect sensors were mounted on a ring 3 cm distal to the magnet. An optimization algorithm based on Newton's method determined the position and orientation of the magnet within the model humerus under various conditions, including bone translations, interference, and magnet misalignment. The orientation of the model humerus was determined within 3° for rotations centered in the arm; an additional 6° error was found for translations 20 mm from center. Adjustments in sensor placement may reduce these errors. The results demonstrate that the OML is a feasible solution for providing prosthesis rotation control while preserving rotational proprioception.

Entities:  

Mesh:

Year:  2010        PMID: 21193382      PMCID: PMC4288921          DOI: 10.1109/TNSRE.2010.2102365

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  13 in total

1.  Implantable transducer for two-degree of freedom joint angle sensing.

Authors:  M W Johnson; P H Peckham; N Bhadra; K L Kilgore; M M Gazdik; M W Keith; P Strojnik
Journal:  IEEE Trans Rehabil Eng       Date:  1999-09

Review 2.  Osseointegration in skeletal reconstruction and rehabilitation: a review.

Authors:  R Brånemark; P I Brånemark; B Rydevik; R R Myers
Journal:  J Rehabil Res Dev       Date:  2001 Mar-Apr

3.  Intelligent multifunction myoelectric control of hand prostheses.

Authors:  C M Light; P H Chappell; B Hudgins; K Engelhart
Journal:  J Med Eng Technol       Date:  2002 Jul-Aug

4.  Results of humeral stump angulation osteotomy.

Authors:  E Neusel; M Traub; K Bläsius; E Marquardt
Journal:  Arch Orthop Trauma Surg       Date:  1997       Impact factor: 3.067

5.  The angulation osteotomy of above-elbow stumps.

Authors:  E Marquardt; G Neff
Journal:  Clin Orthop Relat Res       Date:  1974-10       Impact factor: 4.176

6.  Design and implementation of an implantable goniometer.

Authors:  P R Troyk; R J Jaeger; M Haklin; J Poyezdala; T Bajzek
Journal:  IEEE Trans Biomed Eng       Date:  1986-02       Impact factor: 4.538

7.  Proprioceptive coordination of movement sequences: discrimination of joint angle versus angular distance.

Authors:  L Bevan; P Cordo; L Carlton; M Carlton
Journal:  J Neurophysiol       Date:  1994-05       Impact factor: 2.714

8.  Applications and failure modes of percutaneous devices: a review.

Authors:  A F von Recum
Journal:  J Biomed Mater Res       Date:  1984-04

9.  Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms.

Authors:  Todd A Kuiken; Guanglin Li; Blair A Lock; Robert D Lipschutz; Laura A Miller; Kathy A Stubblefield; Kevin B Englehart
Journal:  JAMA       Date:  2009-02-11       Impact factor: 56.272

10.  Anthropometric measurement of muscle mass: revised equations for calculating bone-free arm muscle area.

Authors:  S B Heymsfield; C McManus; J Smith; V Stevens; D W Nixon
Journal:  Am J Clin Nutr       Date:  1982-10       Impact factor: 7.045

View more
  2 in total

1.  Localization accuracy of multiple magnets in a myokinetic control interface.

Authors:  Marta Gherardini; Francesco Clemente; Stefano Milici; Christian Cipriani
Journal:  Sci Rep       Date:  2021-03-01       Impact factor: 4.996

2.  The myokinetic control interface: tracking implanted magnets as a means for prosthetic control.

Authors:  S Tarantino; F Clemente; D Barone; M Controzzi; C Cipriani
Journal:  Sci Rep       Date:  2017-12-07       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.