Literature DB >> 21192270

CobraPLUS and Cookgas air-Q versus Fastrach for blind endotracheal intubation: a randomised controlled trial.

Wolfgang Erlacher1, Heide Tiefenbrunner, Thomas Kästenbauer, Sylvia Schwarz, Robert D Fitzgerald.   

Abstract

BACKGROUND AND
OBJECTIVE: CobraPLUS and Cookgas air-Q are supraglottic airways expected to allow safe ventilation as well as reliable blind intubation. In a prospective, controlled trial, we hypothesised that quality of ventilation and success rate of blind endotracheal intubation of these new devices would be superior to the Fastrach intubating laryngeal mask airway (ILMA). When blind intubation failed the quality of fibrescope-guided intubation was investigated. To allow identification of those patients in whom blind intubation would be difficult, we investigated the predictive value of currently used predictors for ease of endotracheal intubation.
METHODS: One hundred and eighty adult patients with documented BMI, Mallampati score, Cormack-Lehane classification, interincisor gap and thyromental distance were randomised into three groups according to the device used. Ventilation conditions were rated as excellent, good or difficult. When blind intubation failed, fibrescope-guided intubation conditions were rated as well. Statistical analysis was performed by a χ-test.
RESULTS: The quality of ventilation was excellent for all devices. Three patients in the CobraPLUS group and two patients in the ILMA and the Cookgas groups needed a slight reposition. Blind intubation through the CPLA was successful in 47%, through the Cookgas in 57%, whereas the Fastrach group had a success rate of 95%. Fibreoptic intubation was possible in all but one patient. None of the registered scores and measures allowed prediction of difficult blind intubation.
CONCLUSION: All devices appeared to be safe airways. The Fastrach ILMA proved to be a reliable facilitator for blind intubation. CobraPLUS and Cookgas air-Q allowed an easy fibrescopic intubation. Failed blind intubations could not be predicted by the used parameters.

Entities:  

Mesh:

Year:  2011        PMID: 21192270     DOI: 10.1097/EJA.0b013e328340c352

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  9 in total

1.  The air-Q(®) intubating laryngeal airway vs the LMA-ProSeal(TM) : a prospective, randomised trial of airway seal pressure.

Authors:  R E Galgon; K M Schroeder; S Han; A Andrei; A M Joffe
Journal:  Anaesthesia       Date:  2011-08-22       Impact factor: 6.955

Review 2.  Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis.

Authors:  Eun Jin Ahn; Geun Joo Choi; Hyun Kang; Chong Wha Baek; Yong Hun Jung; Young Cheol Woo; Si Ra Bang
Journal:  Biomed Res Int       Date:  2016-06-23       Impact factor: 3.411

3.  Supraglottic airway devices as a strategy for unassisted tracheal intubation: A network meta-analysis.

Authors:  EunJin Ahn; GeunJoo Choi; Hyun Kang; ChongWha Baek; YongHun Jung; YoungCheol Woo; SiRa Bang
Journal:  PLoS One       Date:  2018-11-05       Impact factor: 3.240

4.  The difficult airway with recommendations for management--part 1--difficult tracheal intubation encountered in an unconscious/induced patient.

Authors:  J Adam Law; Natasha Broemling; Richard M Cooper; Pierre Drolet; Laura V Duggan; Donald E Griesdale; Orlando R Hung; Philip M Jones; George Kovacs; Simon Massey; Ian R Morris; Timothy Mullen; Michael F Murphy; Roanne Preston; Viren N Naik; Jeanette Scott; Shean Stacey; Timothy P Turkstra; David T Wong
Journal:  Can J Anaesth       Date:  2013-10-17       Impact factor: 5.063

5.  Extraglottic airway devices: A review.

Authors:  Ramesh Ramaiah; Debasmita Das; Sanjay M Bhananker; Aaron M Joffe
Journal:  Int J Crit Illn Inj Sci       Date:  2014-01

6.  Air-Q intubating laryngeal airway: A study of the second generation supraglottic airway device.

Authors:  Viren Bhaskar Attarde; Nalini Kotekar; Sarika M Shetty
Journal:  Indian J Anaesth       Date:  2016-05

7.  Comparison of success rate of intubation through Air-Q with ILMA using two different endotracheal tubes.

Authors:  S K Malhotra; K V Bharath; Vikas Saini
Journal:  Indian J Anaesth       Date:  2016-04

8.  Comparison of the Success Rate of Intubation Between the LMA Fastrach and AirQ-ILA Methods in Patients Undergoing Elective Surgery During General Anaesthesia.

Authors:  Seydalireza Seyed Siamdoust; Faranak Rokhtabnak; Soudabeh Djalali Motlagh; Poupak Rahimzadeh; Valiollah Hassani; Mahdi Farnaghizad
Journal:  Anesth Pain Med       Date:  2018-08-11

9.  Comparison of blind intubation via supraglottic airway devices versus standard intubation during different airway emergency scenarios in inexperienced hand: Randomized, crossover manikin trial.

Authors:  Andrzej Bielski; Eva Rivas; Kurt Ruetzler; Jacek Smereka; Mateusz Puslecki; Marek Dabrowski; Jerzy R Ladny; Michael Frass; Oliver Robak; Togay Evrin; Lukasz Szarpak
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817