Real-time electrogram analysis for monitoring coronary blood flow during human ventricular fibrillation: implications for CPR.

Karthikeyan Umapathy1, Farbod H Foomany, Paul Dorian, Talha Farid, Gopal Sivagangabalan, Krishnakumar Nair, Stephane Masse, Sridhar Krishnan, Kumaraswamy Nanthakumar.   

Abstract

BACKGROUND: Effective chest compressions during prolonged ventricular fibrillation (VF) have been shown to increase the chances of successful defibrillation to a rhythm associated with a sustainable cardiac output. There is currently no effective method of recording the degree of antegrade coronary artery flow during chest compression in VF.
OBJECTIVE: This study sought to quantify the relationship between the antegrade coronary flow and the characteristics of human VF using near real-time wavelet-based electrocardiographic markers.
METHODS: VF experiments were conducted in 8 isolated human hearts. The Langendorff perfusion enabled different flow rates (perfusion) during VF, which allowed for the simulation of chest compression with different efficacies. After the initiation of VF, the hearts were maintained in ischemia (no flow) for 3 minutes, followed by a 2-minute reperfusion and defibrillation. The experiments were repeated at flows of 0%, 30%, and 100% of baseline perfusion, and volume-conducted surface electrograms were recorded and analyzed using continuous wavelet transform in 5-second frames.
RESULTS: Near real-time wavelet features were derived that demonstrated significant differences in the multicomponent nature of VF signals and predicted perfusion rate characteristics for different flow rates (i.e., 0%, 30%, and 100%; P < .0006). A pattern classifier was trained using the feature values from 5 hearts, and the flow rates for 3 additional hearts were predicted with an accuracy of 90%.
CONCLUSION: VF electrogram characteristics as measured by wavelet analysis relate to antegrade coronary flow rate during VF. These findings suggest that chest compression efficacy of physiological importance could be monitored using near real-time wavelet analysis.
Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21185950     DOI: 10.1016/j.hrthm.2010.12.033

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  3 in total

1.  Studying semblances of a true killer: experimental model of human ventricular fibrillation.

Authors:  K Nair; T Farid; S Masse; K Umapathy; S Watkins; K Poku; J Asta; M Kusha; E Sevaptsidis; J Jacob; J S Floras; K Nanthakumar
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-01-20       Impact factor: 4.733

2.  Spectral analysis-based risk score enables early prediction of mortality and cerebral performance in patients undergoing therapeutic hypothermia for ventricular fibrillation and comatose status.

Authors:  David Filgueiras-Rama; Conrado J Calvo; Óscar Salvador-Montañés; Rosalía Cádenas; Jose Ruiz-Cantador; Eduardo Armada; Juan Ramón Rey; J L Merino; Rafael Peinado; Nicasio Pérez-Castellano; Julián Pérez-Villacastín; Jorge G Quintanilla; Santiago Jiménez; Francisco Castells; Francisco J Chorro; J L López-Sendón; Omer Berenfeld; José Jalife; Esteban López de Sá; José Millet
Journal:  Int J Cardiol       Date:  2015-03-14       Impact factor: 4.164

Review 3.  Optimal antiarrhythmic drug therapy for electrical storm.

Authors:  Dan Sorajja; Thomas M Munger; Win-Kuang Shen
Journal:  J Biomed Res       Date:  2015-01-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.