Literature DB >> 21177064

Scintigraphic evaluation of rhBMP-2-biocoated implants reveals no ectopic bone formation.

L J Lehmann1, A Werner, D J Dinter, E Mauermann, R Seidling, J Brade, M Laub, S Luers, S Madenci, H Jennissen, U Obertacke, H P Scharf, M L Schwarz.   

Abstract

The main objectives of the study described below were of two-fold nature: (1) to examine if rhBMP-2-biocoated implants in a pig model could lead to ectopic bone formation and (2) if quantitative and/or qualitative differences could be found between adhesively and covalently bonded BMP II using the scintigraphic method. In order to examine these central questions, 26 Göttingen minipigs were allocated to three groups with a control group (n=7) and two study groups (n=9 each) receiving one of three implant types: (a) chromosulfuric acid treated titanium surface as control, (b) non-covalently bonded BMP-2, and (c) covalently bonded and immobilized rhBMP-2. Each animal received four barbell-shaped implants, one in the proximal and distal metaphysis of each femur. The scintigraphic analyses were conducted after four, eight, and 12 weeks postoperatively. The visual (qualitative) analysis failed to show ectopic bone formation in any of the three groups. The statistical analysis of the relative values for bone formation yielded no significant differences between the groups, although the limitation in the applied methods do not enable one to draw conclusions regarding the histomophometric results.
Copyright © 2010 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21177064     DOI: 10.1016/j.biopha.2010.10.008

Source DB:  PubMed          Journal:  Biomed Pharmacother        ISSN: 0753-3322            Impact factor:   6.529


  3 in total

Review 1.  Bone Morphogenetic Protein Coating on Titanium Implant Surface: a Systematic Review.

Authors:  Haim Haimov; Natali Yosupov; Ginnady Pinchasov; Gintaras Juodzbalys
Journal:  J Oral Maxillofac Res       Date:  2017-06-30

2.  Analysis of the osseointegrative force of a hyperhydrophilic and nanostructured surface refinement for TPS surfaces in a gap healing model with the Göttingen minipig.

Authors:  Roland Seidling; Lars J Lehmann; Manuel Lingner; Eckhard Mauermann; Udo Obertacke; Markus L R Schwarz
Journal:  J Orthop Surg Res       Date:  2016-10-17       Impact factor: 2.359

3.  Osseointegrative effect of rhBMP-2 covalently bound on a titan-plasma-spray-surface after modification with chromosulfuric acid in a large animal bone gap-healing model with the Göttingen minipig.

Authors:  Manuel Lingner; Roland Seidling; Lars Johannes Lehmann; Eckhard Mauermann; Udo Obertacke; Markus Ludwig Rupert Schwarz
Journal:  J Orthop Surg Res       Date:  2018-08-30       Impact factor: 2.359

  3 in total