Literature DB >> 21175021

A comparative assessment of the forces and moments generated at the maxillary incisors between conventional and self-ligating brackets using a reverse curve of Spee NiTi archwire.

Iosif Sifakakis1, Nikolaos Pandis, Margarita Makou, Theodore Eliades, Christoph Bourauel.   

Abstract

OBJECTIVES: To compare the intrusive forces and labio-palatal moments generated at the maxillary incisors by a 0.017 x 0.025 inch reverse curve NiTi wire using self-ligating and conventional brackets.
METHODS: Ten 0.017 x 0.025 inch reverse curve NiTi archwires were used with each of the following 0.022 inch bracket systems: Titanium Ortho (Ormco/Sybron, CA, USA), In-Ovation R (GAC International, NY, USA) and Damon System 3MX (Ormco/Sybron, CA, USA). The wires were inserted on bracketed maxillary Frasaco models, with segmented maxillary incisors. Simulated intrusion from 0.0-1.0 mm was performed on the Orthodontic Measurement and Simulation System, which recorded the intrusive forces and the labio-palatal moments at 0.05 mm increments. The data were analysed with the ANOVA and Scheffe tests.
RESULTS: The intrusive forces were significantly different between all bracket types. The highest force was recorded with the conventional Titanium Orthos brackets (8.2 N), followed by the Damon 3MX brackets (6.3 N) and the In-Ovation R brackets (5.5 N). The moments were found to be significantly different between the conventional and the self-ligating brackets, but not between the two types of self-ligating brackets. The highest moments were recorded with the self-ligating brackets (16.6-16.9 N/mm), followed by the conventional brackets (10.8 N/mm).
CONCLUSIONS: The intrusive forces exerted on the maxillary incisors by a 0.017 x 0.025 inch reverse curve NiTi archwire during the final 1 mm of levelling are very high and beyond the necessary intrusive force level for these teeth. Lower intrusive forces, but higher labio-palatal moments, were recorded with the self-ligating brackets.

Mesh:

Substances:

Year:  2010        PMID: 21175021

Source DB:  PubMed          Journal:  Aust Orthod J        ISSN: 0587-3908


  3 in total

1.  Comparative assessment of dental and basal arch dimensions of passive and active self-ligating versus conventional appliances : A randomized clinical trial.

Authors:  Mohannad M Alabdullah; Ahmad S Burhan; Alaa Nabawia; Fehmieh Nawaya; Humam Saltaji
Journal:  J Orofac Orthop       Date:  2022-07-05       Impact factor: 1.938

2.  Torque efficiency of square and rectangular archwires into 0.018 and 0.022 in. conventional brackets.

Authors:  Spyridon N Papageorgiou; Iosif Sifakakis; Ioannis Doulis; Theodore Eliades; Christoph Bourauel
Journal:  Prog Orthod       Date:  2016-01-15       Impact factor: 2.750

3.  Variability of slot size in orthodontic brackets.

Authors:  Clémentine Lefebvre; Hassan Saadaoui; Jean-Marc Olive; Stéphane Renaudin; Fabienne Jordana
Journal:  Clin Exp Dent Res       Date:  2019-07-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.