Literature DB >> 21173532

Physiological strains of wearing aluminized and non-aluminized firefighters' protective clothing during exercise in radiant heat.

Chinmei Chou1, Yutaka Tochihara, Mohamed Saat Ismail, Joo-Young Lee.   

Abstract

This study examined the influences of aluminized (Type A) and non-aluminized firefighters' protective clothing (Type B, C, D and CON) on physiological and subjective responses in radiant heat. Total clothing weight was 6.24, 6.38, 6.06, 5.76 and 3.82 kg for Type A, B, C, D and CON, respectively. Eight firefighters performed exercise at an air temperature of 30°C with 50%RH. Three bouts of 10 min-bicycle exercise in radiant heat (a globe temperature of 70°C) was spaced by a 10 min rest with no radiant heat. Results showed that rectal temperature, mean skin temperature, heart rate, and body weight loss were significantly greater in Type A than in other types (p<0.05). For Type A, thermal gradient of the body reached 0.0 ± 0.7°C, heart rate showed a maximum level of 183 ± 11 bpm and 1.9% of body weight was lost due to sweat secretion. Firefighters felt the hottest and most discomfort in Type A. It appeared that firefighters' thermoregulatory mechanism was severely challenged by wearing aluminized protective clothing during exercise in strong radiant heat. Therefore, it is suggested that the safe upper limits while wearing aluminized firefighters' clothing should be distinguished from those for typical firefighters' protective clothing.

Entities:  

Mesh:

Year:  2010        PMID: 21173532     DOI: 10.2486/indhealth.ms1034

Source DB:  PubMed          Journal:  Ind Health        ISSN: 0019-8366            Impact factor:   2.179


  4 in total

1.  Functional Performance of Firefighters After Exposure to Environmental Conditions and Exercise.

Authors:  Kenneth E Games; Zachary K Winkelmann; Kaitlin D McGinnis; Jeremy S McAdam; David D Pascoe; JoEllen M Sefton
Journal:  J Athl Train       Date:  2019-12-26       Impact factor: 2.860

Review 2.  Skin Temperature Measurement Using Contact Thermometry: A Systematic Review of Setup Variables and Their Effects on Measured Values.

Authors:  Braid A MacRae; Simon Annaheim; Christina M Spengler; René M Rossi
Journal:  Front Physiol       Date:  2018-01-30       Impact factor: 4.566

Review 3.  A review of test methods for evaluating mobility of firefighters wearing personal protective equipment.

Authors:  Yutaka Tochihara; Joo-Young Lee; Su-Young Son
Journal:  Ind Health       Date:  2022-01-12       Impact factor: 2.179

Review 4.  Characterization and Modeling of Thermal Protective and Thermo-Physiological Comfort Performance of Polymeric Textile Materials-A Review.

Authors:  Sumit Mandal; Nur-Us-Shafa Mazumder; Robert J Agnew; Guowen Song; Rui Li
Journal:  Materials (Basel)       Date:  2021-05-05       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.