Surgical repair of rupture of the membranous septum after blunt chest trauma.

Amine Tarmiz1, Stéphane Lopez, Ben Honton, Béatrice Riu.   

Abstract

Rupture of the membranous septum is a very rare complication of blunt chest trauma. In this report, we describe a 22-year-old man who sustained multiple blunt trauma injuries during a motor vehicle accident. Rupture of the membranous septum was diagnosed 48 hours after the initial trauma and the defect was closed with Gore-Tex (W.L. Gore & Assoc, Flagstaff, AZ). However, the operation was complicated by complete atrioventricular block requiring implantation of a permanent DDD pacemaker.
Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21172472     DOI: 10.1016/j.athoracsur.2010.08.073