Literature DB >> 21169298

Assessing angulation on digital images of radiographs of fractures of the distal radius: visual estimation versus computer software measurement.

G A J Robertson1, B F M Robertson, B Thomas, J McEachan, D M Davidson.   

Abstract

We assessed the reliability of visual estimation of angles on computer images of radiographs, and compared their accuracy with the measurement of angles using computer software for ten distal radius fractures. We asked 73 clinicians to visually estimate the dorsal angulation on ten computerized radiographs of fractures of the distal radius. The reliability of these estimations was calculated. Their accuracy was compared to a 'gold standard' obtained by consensus agreement between three consultants measuring these angles using the software. Inter-observer reliability was calculated as ICC = 0.51 and intra-observer reliability as r = 0.76. The visual estimations were less accurate with a mean percentage error of 31% (range, 7-83%). As angulation increased the estimation accuracy improved. Although reliability and accuracy of such estimation was better for clinicians with greater experience, actual measurement was more reliable and accurate.

Entities:  

Mesh:

Year:  2010        PMID: 21169298     DOI: 10.1177/1753193410391361

Source DB:  PubMed          Journal:  J Hand Surg Eur Vol        ISSN: 0266-7681


  5 in total

1.  Estimation of radiographic measurements in fracture distal radius. Should we be using digital measuring tools?

Authors:  Simon Nicholson; Bijayendra Singh
Journal:  J Clin Orthop Trauma       Date:  2012-06

2.  Radiographs Versus Radiographic Measurements in Distal Radius Fractures.

Authors:  Valentin Neuhaus; Arjan G Bot; Thierry G Guitton; David C Ring
Journal:  J Hand Microsurg       Date:  2014-10-21

3.  Accuracy and Reliability of Radiographic Estimation of Volar Lip Fragment Size in PIP Dorsal Fracture-Dislocations.

Authors:  Daniel S Donovan; Jeremy D Podolnick; Wayne Reizner; O Alton Barron; Louis W Catalano; Steven Z Glickel
Journal:  Hand (N Y)       Date:  2018-06-05

4.  Improved precision of radiographic measurements for distal radius fractures after a technique-teaching tutorial.

Authors:  Shandy Fox; Geoffrey Johnston; Samuel Stewart
Journal:  Can J Surg       Date:  2020-05-21       Impact factor: 2.089

5.  Internal plate fixation versus plaster in displaced complete articular distal radius fractures, a randomised controlled trial.

Authors:  Marjolein A M Mulders; Monique M J Walenkamp; J Carel Goslings; Niels W L Schep
Journal:  BMC Musculoskelet Disord       Date:  2016-02-09       Impact factor: 2.362

  5 in total