Literature DB >> 21168617

Early kidney graft size and Doppler parameters are associated with kidney graft function 1 year after transplantation.

J Buturovic-Ponikvar1, S Cerne, M Arnol, A Kandus, R Ponikvar, A Bren.   

Abstract

BACKGROUND: The aim of this study was to assess the association of various ultrasonography (US) and Doppler parameters of kidney graft as measured at 1 month posttransplant with 1-year graft function.
MATERIALS AND METHODS: The study cohort included 125 adult recipients of deceased donor kidney transplantations between January 2006 and February 2009. All patients underwent an US-Doppler examination performed by a trained nephrologist at 1 month posttransplant using an Acuson-Siemens Sequoia 512. Graft length and intrarenal Doppler indices were measured at the midsegmental artery level. Relative graft size was calculated by dividing graft length with body mass index. Graft function was assessed at 1 year by estimated glomerular filtration rate (eGFR) using the 4-variable Modification of Diet in Real Disease study equation. Linear and logistic regression analyses were used to assess the relationship between US-Doppler parameters and eGFR.
RESULTS: Univariate linear regression showed a significant correlation between eGFR at 1 year and graft length at 1 month (P = .009), relative graft length <0.50 cm per kg/m(2) (P = .004), resistance index >0.75 (P = .031), and end-diastolic velocity <9 cm/sec (P = .006). Logistic regression analyses showed that eGFR <60 mL/min/1.73 m(2) at 1 year was significantly associated with graft length <12 cm at 1 month (odds ratio [OR], 2.4; 95% confidence interval [CI], 1.16-4.92; P = .017), relative graft length <0.5 cm per kg/m(2) (OR, 2.54; 95% CI, 1.20-5.35; P = .014), resistance index >0.75 (OR, 2.86; 95% CI, 1.30-6.29; P = .009), and end-diastolic velocity <9 cm/sec (OR, 2.37; 95% CI, 1.01-5.56; P = .047).
CONCLUSION: In this retrospective analysis, kidney transplant recipients with greater graft length at 1 month, specifically when standardized to body size, showed better graft function at 1 year posttransplantation. Higher intrarenal diastolic blood flow and lower resistance index at 1 month were also predictive of better graft function at 1 year.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21168617     DOI: 10.1016/j.transproceed.2010.09.053

Source DB:  PubMed          Journal:  Transplant Proc        ISSN: 0041-1345            Impact factor:   1.066


  3 in total

1.  Does size matter? Kidney transplant donor size determines kidney function among living donors.

Authors:  Meenakshi Narasimhamurthy; Lachlan M Smith; Jason T Machan; Steven E Reinert; Reginald Y Gohh; Lance D Dworkin; Basma Merhi; Nikunjkumar Patel; Michael D Beland; Susie L Hu
Journal:  Clin Kidney J       Date:  2016-10-04

Review 2.  Current status of imaging diagnosis in the transplanted kidney. A review of the literature with a special focus on contrast-enhanced ultrasonography.

Authors:  Maria Ramona Bădulescu; Mihai Adrian Socaciu; Tudor Moisoiu; Alexandra Andries; Gheorghiţă Iacob; Radu Badea
Journal:  Med Pharm Rep       Date:  2020-04-22

3.  Early ultrasound assessment of renal transplantation as the valuable biomarker of long lasting graft survival: a cross-sectional study.

Authors:  Ahmad Enhesari; Saeid Mardpour; Zohreh Makki; Soura Mardpour
Journal:  Iran J Radiol       Date:  2014-01-30       Impact factor: 0.212

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.